Main offers covering
Cable accessories, Capacitors&Controller, Contactors&Thermal Relays, more info please click as follows.
Offer List
(Total 27 Offers)
Power range:
220V grade 0.75-3.7 KW
380 V grade 0.75-280KW
Output frequency: 0-400Hz
Over loading capacity: 150% rating current of 1 minute
Model Meaning:
ZVF7/9-P/G
7/9...
[Expiration Date: 2009-03-05]
LR2-D series of thermal overload relay can be used in the circuit of 50Hz or 60Hz, rated insulation voltage 660V, rated current 0.1-140A for protecting the phase break when the ele...
[Expiration Date: 2009-03-05]
RN series inverter is one of the most advanced D/C-A/C converters all over the world. Main advantage is, output high quality Sine Wave Inverter A/C electricity. Microcomputer contr...
[Expiration Date: 2009-01-09]
These special products of AVR series voltage stabilizers have advanced equipment, abundant technology, reliable quality and distinguish credit. They are suitable for families, scho...
[Expiration Date: 2009-03-05]
XB2/XB4/XB7 sieres Pushbutton
Flush Push button switches
Projecting pushbutton switches
Mushroom Pushbutton switches
Rotary push button switches and so on.
[Expiration Date: 2009-03-07]
NT low voltage H. R. C. Fuse has features of light in weight, small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and shor...
[Expiration Date: 2009-03-05]
MRM3 moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacture technology. They are suitable f...
[Expiration Date: 2009-03-05]
LC1-D(New) series AC Contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently startin...
[Expiration Date: 2009-03-05]
Technical Data
Operating Voltage: Three-phase 380VAC 50/60HZ
Value & Action time of Over voltage: 380V¡ª460VAC 1.5-4S
Value &Action time of Under voltage: 300V¡ª380VAC 2-9S
Ac...
[Expiration Date: 2009-03-05]
Metal Distribution Box,
Hight: 200 to 1800mm
Width: 200 to 1000mm
Depth: 150 to 400mm
Thickness:
Door: 1.2/1.5/2.0mm
Body: 1.2/1.5mm
MP/mm: 2.0M. P
Note:
It also can ...
[Expiration Date: 2009-09-05]
Ammeter
Voltmeter
Analoge meter
Panel Meter
Digital Meter, etc.
[Expiration Date: 2009-03-05]
Switching Mode Power Supply
Output Mode: Single/dual/triplequad
Capacity Mode: SA10W to SA1200W
Input voltage: 176 to 264VAC. Selected by swich
Output voltage: The voltage we a...
[Expiration Date: 2009-03-05]
Application
Limiting switches are ideal electrical and other industries. They have complete specifications and various types, compact structure, nice appearance, excellent perform...
[Expiration Date: 2009-03-05]
RFT-342R is the latest four ports VoIP ATA from RAFON Technology. RFT-342R supports the wildly used industrial standards, both SIP and H. 323, in a single firmware. Switch to diffe...
[Expiration Date: 2009-07-01]
BK3 Series Machine tool Contra Transformer, Generally being vertically mounted, this series of transformer can continuously work at ratings. Widely used as the power source to cont...
[Expiration Date: 2009-03-05]
NYLON CABLE CLAND
Material: UL Nylon 6/6; Neoprene for seal insert, with nut
Color: Black, gray, light gray.
Protection: IP68 Temp. Resistance: -30 to 80 degree; Short time 14...
[Expiration Date: 2009-03-05]
MRB-30L is applicable to protect line conductor and overload, and short-circuit of small sealed motors, it is mainly used for protection of circuits with AC 230Vand 50Hz/60Hz, and ...
[Expiration Date: 2009-03-05]
MRW38(LW38) universal changeover switch is mainly applicable to 50HZ AC550V or DC 440 for changing the circuit. And Our company also manufacture CA10, LW5, LW8, LW28 changeover swi...
[Expiration Date: 2009-03-05]
Electric heat capacitor is mainly used in the medium-frequency induction heating electric system, for raising power factor and improving circuit property. Electric heat capacitor i...
[Expiration Date: 2009-05-26]
RFT-382R is the latest eight ports VoIP ATA backup from RAFON Technology. RFT-382R supports the wildly used industrial standards, both SIP and H. 323, in a single firmware. Switch ...
[Expiration Date: 2009-07-01]
Specifications:
1) Protection class: Provides B
2) Composite type: 1P, 1P+N, 2P+N, 3P+N, 3P+NPE
3) Max. Continuous operating voltage (Uc): 255V~/275V~/320V~/385V~/440V~
4) No...
[Expiration Date: 2009-09-05]
Kind: Common, Oil filled, Cold media.
Accurrancy: 1.6%, 2.5%
Measuring range: 0-600kg/cmm
Outer size: 1", 1.5", 2", 2.5", 3", 3.5", 4", 6"
Casing: Plastic, Stainless Steel
Ma...
[Expiration Date: 2009-03-05]
SN series contactor
SK series contactor
SC series contactor
[Expiration Date: 2009-01-08]
Aplication:
Products which power are less than 5000W, like refrigeratory, mill machine, electric saw, air compressor and weeding machine, etc.
Protection:
Overload protecti...
[Expiration Date: 2009-03-05]
Open Power Voltage Voc(V): 21.6/43.2
Optimum Power Voltage Vmp(V) 17.2/34.4
Maximum Power Wp(W): 50-240
[Expiration Date: 2009-09-12]
Application:
RPCF series reactive power auto compensation controllers is suitable for automatically adjusting of low voltage distribution system capacitor compensating device to ...
[Expiration Date: 2009-03-03]
GV series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-v...
[Expiration Date: 2009-09-05]