MIC Chinese Simplified Chinese Traditional English
Inquiry Basket Inquiry Basket (0) item | Recent Visit History | Join Audited Suppliers

Home » Product Directory » Electrical & Electronics » Power Supply & Distribution » UPS » Online UPS (HP900RT(1-3KVA))

Online UPS (HP900RT(1-3KVA))

Online UPS (HP900RT(1-3KVA))
Online UPS (HP900RT(1-3KVA))

Product Description

HP900RT(1~3KVA)
1: 1 phase
Application:
Rack mounted server and other networking equipment.

Features:
1. Rack and tower convertible
2. High Frequency and double conversion online technology
3. Fully digitized microprocessor control
4. Smart RS232 communication with monitoring software
5. Optional SNMP card slot
6. Wide input voltage range
7. Advanced PFC technology
8. Self-testing when UPS startup
9. Advanced battery management
10. Automatic battery charging in UPS off mode
11. Lighting and surge protection
12. Short circuit and overload protection
13. Fan speed auto control when loads varies
14. Network/fax/modem surge protection
15. Optional extension battery pack
16. LCD display
17. EPO function(optional)

ModelHP910RTHP915RTHP920RTHP930RT
Capacity1KVA/700W1500VA/1050W2KVA/1400W3KVA/2100W
InputVoltage Rangewhen load ≤ 60%, 55Vac ~138Vac (±5V); 60%< load ≤ 70%, 60Vac ~138Vac (±5V); 70%< load ≤ 80%, 70Vac ~138Vac (±5V);   load ≥ 80%, 80Vac ~138Vac (±5V);
Frequency Range  46Hz~54Hz or   56Hz~64Hz
PhaseSingle phase
Power Factor0.95
OutputVoltage Range110 VAC /115VAC/120VAC ±2%
Frequency Range50Hz/60Hz ±0.2%
THD (linear load)<5%
THD (non-linear load)output 110Vac, < 8%;   output 115Vac/120Vac, < 10%
Overload Capability108% ~130% Full load, Beep/0.5s immediately, 30s then fault ,auto-recovery
150% Full load, Beep continuously, 200ms then fault ,auto recovery
Crest Factor3:1(max)
Short Circuit ProtectionBypass mode: 30A NFB(no fuse breaker)
Line/battery mode: Circuit protection, Inverter off , fault
Waveformpure sine wave
Transfer Time Between AC Mode and Battery Mode0ms
Efficiency≥ 85%(AC mode); ≥ 83%(battery mode)
BatteryModel12V sealed lead acid maintenance free
DC Voltage36VDC48VDC96VDC
Battery3×12V/7AH4×12V/7AH8×12V/7.2AH
Backup Time ( half load )12min12min19min16min
Backup Time ( full load )5min5min8min5min
Charge Current(standard unit)0.7A  0.7A  0.7A0.7A
Charge Current(long time unit)7.5A7.5A7.5A7.5A
Recharge Time90% capacity after 8 hrs charging
Communication InterfaceRS232 ; SNMP (optional)
LCD Indication1, Input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA and percent, inverter temperature
2, Operation mode such as “on line”, “on batt”, or “or bypass”
LED Indication1, Green LED for normal operation,
2, Yellow LED for warning condition
3, Red LED for abnormal operation
Noise Level<45dB
EnvironmentTemperature0~40
Humidity0%~95% (non-condensing)
Altitude<1500m
Storage Temperature-25~55
OtherStandard Unit Net/Gross Weight(kg)18/2126/2936/3937/40
Dimension (W×D×H)mm  440×450×86.5440×650×86.5440×550×131
Packing (W×D×H)mm  580×580×207580×780×207580×680×252

More Product Features

   
Model NO.:  HP900RT(1-3KVA)
Standard:  ISO9001, CE
Company: Shenzhen Kstar Science-Technology Co., Ltd.

Click here to send inquiry