Air Circuit Breaker (GSW1)
![]() Air Circuit Breaker (GSW1) |
Product Description
GSW1 series Air Circuit Breakers comply with IEC60947-2 and mainly apply to TN-C, TN-C-S, TN-S power distribution network.
Rated Voltage: 400V AC, 690V AC
Frequency: 50Hz
Rated Current of Frame or Inm (A): 2000, 3200, 4000
Rated Current or In (A): 630, 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000
Rated Ultimate Short Circuit Breaking Capacity or ICU at 400V/ 690V AC for GSW1-2000, GSW1-3200, GSW1-4000 respectively (KA): 80/ 50, 100/ 65, 100/ 65
Rated Service Short Circuit Breaking Capacity or Ics at 400V/ 690V AC for GSW1-2000, GSW1-3200, GSW1-4000 respectively (KA): 50/ 40, 65/ 50, 65/ 50
Rated Short-time Withstand Current at 400V/ 690V AC for GSW1-2000, GSW1-3200, GSW1-4000 respectively (KA): 50/ 50, 65/ 65, 65/ 65
Mechanical life for GSW1-2000, GSW1-3200, GSW1-4000 respectively (times): 2500, 2000, 2000
Electrical life for GSW1-2000, GSW1-3200, GSW1-4000 respectively: 500, 500, 500
Poles: 3P or 4P or 3P+N
1. Intelligent Controller with long time tripping, short time tripping and instaneous tripping
Rated voltage: 230V AC or 400V AC or 220V DC
2. UVT (undervoltage release/ undervoltage tripping device). There are instantaneous trip and delayed trip. Delay time is 1-20s, adjustable. Within halh of delay time, the voltage of main circuit recovers to 85% of rated voltage or above, the Circuit breaker won't be open.
Reated Voltage (Ue): 400V AC or 230V AC
Tripping violtage: From 35 percent to 70 percent of Ue
Power consumption: 12VA
3. Shunt release (shunt tripping device)
Reated Voltage (Ue): 400V AC or 230V AC or 220V DC
Tripping voltage: From 70 percent to 110 percent of Ue
Break time: Less than 30ms
More Product Features
| Model NO.: | GSW1 |
|---|---|
| Standard: | IEC60947-2 |
| Company: | Tianshui 213 Electrical Apparatus Co., Ltd. |
Other products from this company
Most Popular
-

MCB (SA1-G3 Hydraulic Magnetic Circuit breaker)
The KSA range of 3KA AC circuit breakers, are ... -

MCCB (TM4-250A-3P)
Application TM4 moulded case cicuit breaker is ... -

MCB 10kA FDM16-63H
Construction and Feature 1. The state-of-art ...
-

Switchgear, Used to Control and Protect Circuits
Switchgear Working environment accordance with ... -

THQL Circuit Breake
GE TQL THQC THQP THQL Circuit breaker (MCB) ... -

X-Pole Mini Circuit Breakers (L7)
L7 Circuit breaker is used in lighting ...
-

Residual Current Circuit Breaker (RCCB) (SF360)
Residual Current Circuit Breaker(RCCB)F360 ... -

Ploymer Housed Metal Oxide Arrester 9kv 10ka
6-9 KV Product's Characteristics: The Core ... -

LBR38 RCD (NFIN)
LBR38 RCD (NFIN) is in conformity with standards ...
-

Circuit Breaker (BKN-3P)
BKN series circuit breaker is used in lighting ... -

FCM1 Intelligent Universal Circuit Breaker
Specifications FCW1 Intelligent Universal ... -

1pole ~ 4pole C60n Miniature Circuit Breaker, MCB, C60 ...
1POLE ~ 4POLE C60N Miniature Circuit Breaker, ...
-

Circuit Breaker (DZ47-63)
Specification: Certificate; SEMKO, CB, CE ... -

Moulded Case Circuit Breaker (UKM32 Series)
Moulded Case Circuit Breaker 1. Thermal ... -

Thermal Protector (ABR9700-SF)
We are professional thermal protector, motor ...
Quick Products |
Inquiry Basket (