Home » Product List » circuit breaker » Automatic Change-Over Switch (HKKQ3)
Product Details
Automatic Change-Over Switch (HKKQ3)
HKKQ3 qutomatic change-over switch(ATSE)integrates switch and logic control, thus it is not necessary toprovide external controller. This truly electromechani-cilly integrated automatic change-over switch has the following functions such as voltage detection, frequency detection, communication interface, electrical and mechanical interlocking etc, so, automatic control, electrical remote control and emergency manual control can be performed. The operation is carried out through the logic control board, which gives various commands to control the motor and gear-box. The motor drives the accelerator which can take switch-spring power accumulating and instantaneous release, swiftly turns making and breaking the circuit or makes circuit switching. The visible operation status can help you to perform safe operation, increasing extremely the various electrical and mechanical performance.
The shell of switch HKKQ3 is designed into small and compact construction. While the shell of switch HKKQ3 is made of different materials: Its control section is made of metal, but the switching section is made of glass-fibre unsaturated polyester resin, having stronger dielectric property and protective capability as well as safe operation performance. This kind of switch is suitable for the automatic change-over of the main power source and the secondary power source of the power supply system or the automatic change over and safe separation of the 2 sets of load-equipment. This kind of switch has a beautiful, movel and simple structure, a small volume but complete functions, being the best choice among congeneric of products. HKKQ3 series had been already passed the detection of EMC.
CONFORM STANDARD
Example for model selection
HKKQ3-100/4. III~380VIn50A
Automatic change-over switch, Appointed calorifil current is 100A, AC rate voltage 380V, Rate current 50A, 4 poles( 3 poles+on and off neutral pole), Suitable for automatic change And automatic recovery of municipal power oil generator power supply system.
HKKQ3 Series Automatic Change-Over switch complies with the following standards:
Interanational standard
IEC60947-1(1998) Low-voltage switchgear and control gear, part one: General Rules.
IEC60947-3(1999) Low-voltage switchgear and control gear, switches, disconneetors, Switch-dis-connectors and fuse-conbination units.
IEC60947-6(1999) Low-vattage switch equipment and control equipment multi-functionswitch Automatic change-over switch electrical device.
National Standard:
GB/T14048.1-2002 Low-voltage switchgear and control gear, part one: General Rules.
GB/T14048.3-2002 Low-voltage switchgear and contro-lgear, switches, disconneetors, Switch-disconnectors and fuse conbination units.
GB/T14048.11-2002 Low-vattage switch equipment and control equipment multi-function-switch automatic change-over switch electrical device.
| Conventional thermal current Ith (A) | 16-100A | 100A | ||||||||||||
| Rated current In (A) | 16A | 20A | 25A | 32A | 40A | 50A | 63A | 80A | 100 | 20A | 40A | |||
| Rated impulse withstand voltage Ui (V) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
| Dielectric strength (V | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 3000 | 5000 | 5000 | |||
| Rated surge-resistant voltage Uimp KV(installed category IV) | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 8 | 8 | |||
| Rated Working Current (A) | 380V | AV-31 | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 20 | 40 | |
| AC-33 | 16 | 20 | 20 | 25 | 32 | 40 | 40 | 63 | 80 | 20 | 32 | |||
| AC-35 | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 20 | 40 | |||
| 220V | DC-31 | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 20 | 40 | ||
| DC-33 | 16 | 20 | 20 | 25 | 32 | 40 | 40 | 63 | 80 | 20 | 32 | |||
| DC-35 | 16 | 20 | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 20 | 40 | |||
| Motor power P (380V)KW | 8 | 10 | 15 | 15 | 20 | 25 | 30 | 30 | 32 | 10 | 20 | |||
| Rated short-time withstand current(kA Rms)0.1s/1.0s | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | |||
| Rated breaking capability (A Rms) AC3 380V | 125 | 160 | 200 | 250 | 320 | 400 | 500 | 640 | 800 | 160 | 320 | |||
| Rated making capability (A Rms) AC33 380V | 160 | 200 | 250 | 320 | 400 | 500 | 630 | 800 | 1000 | 200 | 400 | |||
| Rated short-current making capability lcm(kA peak value) | 8 | 8 | 8 | 8 | 8 | 8 | 10 | 10 | 10 | 8 | 8 | |||
| Mechanical durability (number of cyclic operation) | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 | |||
| Electric durability COS Ø=0.65 AC33 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 1500 | 1500 | |||
| Change-oner time | I-0-II and II-0-I(s) | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 0.5 | 0.5 | ||
| I-0 and II-0 (s) | 2.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.3 | 0.3 | |||
| Power consumption of electrical control | 24V(DC)(w) | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 50 | 50 | ||
| 220V(AC)(w) | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 50 | 50 | |||
| Moment of operation(Nm) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 15 | 15 | |||
| Weight (kg) | 3 Poles | 5.6 | 5.6 | 5.6 | 5.6 | 5.6 | 5.6 | 5.6 | 5.6 | 5.6 | ||||
| 4 Poles | 5.8 | 5.8 | 5.8 | 5.8 | 5.8 | 5.8 | 5.8 | 5.8 | 5.8 | 4.2 | 4.3 | |||
| Model: | HKKQ3 |
|---|