Home » Product List » A, meter and instrument » Electrosmog Meter
Product Details
Electrosmog Meter
We can supply manometer, electrosmog meter, gauss meter, tesla meter, solar power meter, digital manometer
Tes-92 electrosmog meter
Features
- 50 MHz to 3.5 GHz frequency range.
- for isotropic measurements of electromagnetic fields.
- non-directional (isotropic ) measurement with three-channel measurement probe.
- high dynamic range due to three-channel digital results processing.
- configurable alarm threshold and memory function.
- easy to use
Applications
- high frequency (RF) electromagnetic wave field strength measurement.
- mobil phone base station antenna ratenna radiation power density measurement.
- wireless communication applications (cw, tdma, GSM, dect).
- wireless LAN (wi-fi) detection, installation.
- spy camera, wireless bug finder.
- cellular/cordless phone radiation safety level.
- microwave oven leakage detection.
- personal living environment emf safety.
- RF power measurement for fransmitters.
Electrical specifications
| Measurement method | Digital , triaxial measurement |
| Directional characteristic | Isotropic, triaxial |
| Measurement range selection | One continuous range |
| Display resolution | 0.1mV/m, 0.1 μA/m, 0.01 μW/m2 |
| Setting time | Typically 1s ( 0 to 90% of meas. value) |
| Display refresh rate | Typically 400mS |
| Display type | LCD 4 digit |
| Audible alarm | Buzzer |
| Measurement units | mV/m , V/m , μA/m , mA/m , μW/m2 , mW/m2 |
| Measurement display value | Instantaneous measured value, maximum value or average value since power-on. |
| Measurement average time (in per-set steps) | 4s to 15 minutes |
| Measurement alarm function | Adjustable threshold with ON/OFF |
| Measurement calibration factor CAL | Adjustable |
| Manual data memory and read storage | 99 sets ( only recall by meter ) |
| Battery | 9V |
| Battery life | >15 hours |
| Accessory | 9V battery, carrying case & manual |
| Sensor type | Electric field (E) |
| Frequency range | 50MHz to 3.5 GHz |
| Directional characteristic | Isotropic, 3-dimensional |
| Measurement range (CW signal>50MHz) | 38mV/m to 11V/m |
| Absolute error(@1V/m and 50MHz) | ±1.0dB |
| Frequency response (taking into account typ. CAL factor) | ±1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz) |
| Isotropy deviation | Type. ±1.0dB f>50 MHz |
| Overload limit | 4.2W/m2 (40 V/m) |
| Temperature response(0 to 50 ºC) | ±1.5dB |
| Note | Unless otherwise stated, all specifications hold under the following assumptions: Sinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 ºC±3 ºC; relative air humidity 25% to 75%. |
Inquiry Basket (