Advanced LED Surgical Ceiling Light for Medical Clinics
Contact Supplier
Product Highlights
- High Luminance Output: Center illuminance reaches 130,000-160,000 LUX with adjustable settings for optimal surgical visibility.
- Extended LED Lifespan: Average bulb life is greater than or equal to 60,000 hours, reducing replacement frequency and costs.
- Comprehensive Certifications: Certified with CE, ISO9001, ISO14001, HSAS18001, and TUV for quality and safety assurance.
- OEM/ODM Customization: Supports OEM and ODM services, allowing for brand customization and tailored specifications.
- 1-Year Warranty Coverage: Includes a 1-year warranty with free spare parts provided for after-sale service support.
Product Attributes
- Customization
- Available
- Kind
- Operating Room Equipment
- Certification
- ISO9001/ISO14001/Hsas18001/TUV
- Model NO.
- MX LED 700/500
- Group
- All
- Brand Name
- Mingxu
- Model Number
- Mxled700/500
- Warranty
- 1year
- Certificate
- CE ISO
- MOQ
- 1set
- After-Sale Service
- Free Spare Parts
- Place of Origin
- Shandong, China
- Packing
- Wooden Case
- OEM/ODM
- Yes
- Average Bulb Life (H)
- Greater Than or Equal to 60000
- Bulb Power
- 1W
- Optimum Mounting Height (mm)
- 2800-3000
- Net Weight
- 44.3kg
- Transport Package
- Wooden Box
- Specification
- 1070× 350× 470
- Trademark
- Mingxu
- Origin
- Shandong, China
- HS Code
- 8539510000
- Production Capacity
- 50000PCS/Year
Product Images of Advanced LED Surgical Ceiling Light for Medical Clinics
Find Similar Products
Product Description

| Lamp head model | MXLED 700 | MXLED500 |
| Number of lamp beads | 72 | 39 |
| Center Illuminance(LUX) | 130000-160000 ( adjustable) | 100000-130000 (adjustable) |
| Color Temperature(K) | 4300±500 ( adjustable) | 4300±500 ( adjustable) |
| Color Rendering Index (Ra) | ≥95% | ≥95% |
| Spot distribution diameter(mm) | 80-150 | 80-150 |
| Spot diameter (mm) | 160-300 | 160-300 |
| Light beam depth (mm) | ≥1200 | ≥1200 |
| Irradiance(W/m2) | ≤600 | ≤600 |
| Head temperature rise(ºC) | ≤1 | ≤1 |
| Temperature rise in the surgical working area | ≤2 | ≤2 |
| Operating radius(mm) | ≥2200 | ≥2200 |
| Working radius(mm) | 600-1800 | 600-1800 |
| Supply voltage | 220V±22V 50HZ±1HZ | 220V±22V 50HZ±1HZ |
| Input Power | 150VA | 150VA |
| Average life of lamp(h) | ≥60000 | ≥60000 |
| Lamp power | 1W | 1W |
| Optimum installation height(mm) | 2800-3000 | 2800-3000 |
Product Configuration List: Unveil the comprehensive configuration of the Mingxu Mxled700/500 Medical Operating Light. Each component is meticulously crafted to ensure optimal performance. Explore how each element harmonizes to create an exceptional lighting solution, setting a new standard in the healthcare industry.
| Number | Name | Quantity | Remark |
| 1 | Base | 1 | |
| 2 | Cross arm | 2 | |
| 3 | 360° Balance Arm | 2 | |
| 4 | Lamp holder | 2 | |
| 5 | lamp holder lamp beads | 111 | |
| 6 | Handle | 2 | 2 extra |
| 7 | Hexagon wrench s=3,s=4,s=5,s=6,s=8 | 1 each | |
| 8 | Small flat screwdriver | 1 | |
| 9 | Phillips screwdriver | 1 | |
| 10 | Certificate | 1 | |
| 11 | User Manual | 1 | |
| 12 | Product warranty card | 1 |




1. What is the service life of LED surgical shadowless lamp?
The average life of LED bulbs used in LED surgical shadowless lamps is up to 60,000 hours.
2. How to choose LED surgical shadowless lamp?
- Clarify the specific requirements of the operating room for the shadowless lamp, including requirements in terms of brightness, light color, adjustment flexibility, and ease of use.
- Understand the basic characteristics of LED surgical shadowless lamps, such as high efficiency, long life, and low energy consumption.
- Inspect the brightness and light color to ensure that the brightness of the LED surgical shadowless lamp is high enough to meet the needs of clear observation during surgery.
- Evaluate the adjustment flexibility and ease of use, and check whether the LED surgical shadowless lamp can flexibly adjust the angle and height of the lamp head.
3. What are the maintenance tasks of LED surgical shadowless lamps?
- Regularly check the connection status of each connection part of the surgical shadowless lamp every year to prevent accidents caused by loosening of various parts of the shadowless lamp.
- Tighten the power cord connector at the input and output of the control box and the screws at each connection.
- Adjust the rotation limit of the LED surgical shadowless lamp, the working voltage of the bulb, and the brakes of each joint.
- Check the verticality of the suspension tube and the balance of the suspension system.
- The power supply needs to be cut off after each operation.
- Daily fault repairs must be performed by regular maintenance personnel.
4. What should I do if the LED surgical shadowless lamp fails?
- If the main light is not on and the auxiliary light is on, the main light may be damaged. The main light bulb should be replaced immediately.
- If the light is not on, check whether the fuse is blown and whether the power supply voltage is normal. If both are fine, please ask a professional to repair it.
- For problems such as transformer damage, frequent fuse damage, and deformation of the disinfection handle, professionals should also be asked to repair it.
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI2451823". Items marked "" are certified.
Company Profile
Mingxu Medical is a leading professional manufacturer of operating room, ICU and medical nursing equipment in China. It is a national high-tech enterprise integrating R&D, production, sales and service.
It mainly produces and operates operating room, ICU and bed nursing equipment. The main products are surgical shadowless lamps, operating tables, medical pendants, high-end nursing beds, medical carts, medical cabinets, etc. The products are exported to many countries abroad.
The company has a R&D center of more than 5, 000 square meters and a standardized production workshop of more than 20, 000 square meters in Qufu and Shenzhen, China, respectively. It has a complete R&D, production, quality inspection, after-sales service system, advanced production and inspection equipment. It has successively passed ISO9001/ISO13485, ISO14001/OHSAS18001, CE/TUV/SGS and other certifications, and has more than 30 patents in professional fields. It is a national high-tech enterprise, Shandong Province's "specialized and new" innovation enterprise, Shandong Province's "medical device production quality standardization enterprise", and Shandong Province Medical Device Inspection Center "Technical Cooperation Unit".
The company always adheres to the corporate purpose of "survive by quality, develop by technology", and strictly implements the principle of "reputation first, quality first, service first". We will continue to strengthen management, self-improve, and focus on the medical device industry, serving domestic and foreign customers with the best quality products. We also sincerely welcome friends from home and abroad to visit our factory for guidance!
About Our Factory & Business Background
- Address
- No. 1 East Lingcheng Industrial Park, Qufu City, Jining, Shandong, China
Our Production Capability & Technical Expertise
FAQ
- What is the service life of LED surgical shadowless lamp?
- The average life of LED bulbs used in LED surgical shadowless lamps is up to 60,000 hours.
- How to choose LED surgical shadowless lamp?
- Clarify the specific requirements of the operating room for the shadowless lamp, including requirements in terms of brightness, light color, adjustment flexibility, and ease of use. Understand the basic characteristics of LED surgical shadowless lamps, such as high efficiency, long life, and low energy consumption. Inspect the brightness and light color to ensure that the brightness of the LED surgical shadowless lamp is high enough to meet the needs of clear observation during surgery. Evaluate
- What are the maintenance tasks of LED surgical shadowless lamps?
- Regularly check the connection status of each connection part of the surgical shadowless lamp every year to prevent accidents caused by loosening of various parts of the shadowless lamp. Tighten the power cord connector at the input and output of the control box and the screws at each connection. Adjust the rotation limit of the LED surgical shadowless lamp, the working voltage of the bulb, and the brakes of each joint. Check the verticality of the suspension tube and the balance of the suspensi
- What should I do if the LED surgical shadowless lamp fails?
- If the main light is not on and the auxiliary light is on, the main light may be damaged. The main light bulb should be replaced immediately. If the light is not on, check whether the fuse is blown and whether the power supply voltage is normal. If both are fine, please ask a professional to repair it. For problems such as transformer damage, frequent fuse damage, and deformation of the disinfection handle, professionals should also be asked to repair it.
- What is the center illuminance of the lamp?
- The center illuminance is 130,000-160,000 LUX for the MXLED 700 model and 100,000-130,000 LUX for the MXLED 500 model, both of which are adjustable.
- What is the minimum order quantity (MOQ)?
- The minimum order quantity is 1 set.
- What is the warranty period and after-sale service?
- The warranty period is 1 year, and the after-sale service includes free spare parts.
Send your message to this supplier
People who viewed this also viewed
-
US$800.00-900.00 / Piece
-
US$2,100.00-2,500.00 / Piece
-
US$950.00-1,000.00 / Set
-
US$900.00-1,000.00 / Piece
-
US$11,000.00 / Piece
-
US$2,400.00-2,500.00 / Set
-
US$3,980.00 / Set
Find Similar Products By Category
- Supplier Homepage
- Products
- LED surgical light
- Petal type surgical light
- Advanced LED Surgical Ceiling Light for Medical Clinics
Related Categories
Hot Searches
- Surgical Supplies
- Medical Surgical Factories
- Surgical Equipment Factories
- Surgical Gown Factories
- Surgical Lights
- Medical Surgical Lights
- Surgical Operating
- Surgical Equipment Light
- Operating Medical Light
- Premium Surgical Light Bulkbuy