Product Highlights

  • Arc Fault Detection: Identifies and deactivates electrical arcs to prevent fire hazards in residential and commercial settings.
  • Multi-Protection Function: Provides circuit-breaker failure protection, overcurrent protection, overvoltage protection, and arc detection.
  • 485 Communication: Supports Modbus-RTU protocol for remote monitoring and data exchange via LCD display.
  • High Breaking Capacity: Rated short-circuit breaking capacity of 4.5 kA ensures reliable performance under fault conditions.
  • DIN Rail Mounting: Easy installation on standard 35mm DIN rails with compact dimensions for 1P to 4P configurations.
  • Robust Immunity: High immunity to electrostatic discharge, fast transients, and surge impacts for stable operation.
  • Wide Voltage Range: Operates on AC 230V with rated current up to 63A, suitable for various low-voltage applications.
  • Compliance Ready: Meets regulatory requirements for AFCB in new constructions and integrates into older homes per building codes.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention

Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention pictures & photos
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
  • Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
    Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention

Find Similar Products

Product Description

Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
An Arc Fault Circuit Breaker (AFCB), also known as an Arc Fault Detection Device (AFDD), is a specialized circuit breaker designed to identify and deactivate electrical arcs that pose a fire hazard. Unlike standard circuit breakers, which are triggered solely by overloads or short circuits, AFCB possess heightened sensitivity to detect arc faults.

Key information regarding AFCB includes the following:

Functionality:
AFCB operates by recognizing the distinct characteristics of an arc fault, which occurs when electrical current bypasses the intended load and arcs between conductors. Upon detection, the AFCB interrupts the electrical flow to prevent the potential ignition of a fire.

Regulatory Requirements:
AFCB is mandated in numerous new residential constructions and are increasingly being integrated into older homes. The specific requirements for AFCB installation are determined by the building codes applicable within the respective jurisdiction.

Troubleshooting a Tripping AFCB:
In instances where an AFCB frequently trips, it is advisable to disconnect appliances, switch off lights, and examine the wiring for any issues. Should the AFCB continue to trip despite these measures, it may indicate a malfunction or obsolescence, necessitating replacement.
  
Item Specification
Model LD-AFDD
Operating Power Supply AC 230V
Rated Frequency 50Hz
Monitoring  Alarm Alarms for fault arcs with loads below AC 63A
 
Rated Voltage AC 230V
Rated Current AC 63A and below
Dimensions 1P :36*104*75    2P:54*104*75   3P+N :72*104*75    4P:90*104*75
Mounting Method 35mm DIN rail mounting
RUN Indicator Blinks during normal operation
Rated Short-Circuit Breaking Capacity icn (KA): 4.5
Protection Class I P20
Wiring Capacity 1~25 mm2
Tripping Characteristics C,D
Electrostatic Discharge Immunity Air Discharge > 8; Contact Discharge > 6
Electrical Fast Transient/Burst Immunity 4 KA
Surge Impact Immunity 4 KA
Operating Ambient Temperature -23~+ 55ºC
Resistance to Damp Heat Class 2
Pollution Degree 2
Installation Type M Class
Altitude 2000m
Installation Environment Locations with no significant vibration and shock
 
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention
Leidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire PreventionLeidun Afdd Afci Arc Fault Circuit Breaker Arc Fault Protection Fire Prevention

 
 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASI2432494". Items marked "verified" are certified.

Watch Video
Watch Video
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd
Zhejiang Leidun Electric Co., Ltd

About Our Factory & Business Background

Address
Xiamen Village, Liushi Town, Yueqing City, Wenzhou, Zhejiang, China
Nearest Port
Ningbo, Shanghai

Our Production Capability & Technical Expertise

Main Products
Automatic Transfer Switch, Surge Protector, Distribution Box, EV Charger, Circuit Breaker, Electric Meter, Junction Box

Our Industry Experience & Global Business Record

Export Year
2023-06-09
Main Markets
North America, Africa, Mid East

FAQ

What is the primary function of the Arc Fault Circuit Breaker?
It identifies and deactivates electrical arcs that pose fire hazards, offering protection beyond standard overload or short circuit breakers.
What are the protection features included?
It includes circuit-breaker failure protection, overcurrent protection, overvoltage protection (OVP), and detection of current, voltage, and arcs.
How is the device installed?
It is designed for 35mm DIN rail mounting, making installation easy and compatible with standard electrical panels.
What communication protocols are supported?
The device supports 485 Communication and Modbus-RTU protocol, allowing for remote monitoring and data exchange.
What is the rated short-circuit breaking capacity?
The rated short-circuit breaking capacity (icn) is 4.5 kA, ensuring reliable performance during fault conditions.
What are the operating voltage and current ratings?
It operates on AC 230V with a rated frequency of 50Hz and supports rated currents of AC 63A and below.
What should be done if the AFCB frequently trips?
Disconnect appliances, switch off lights, and examine wiring. If it continues to trip, it may indicate a malfunction requiring replacement.