| Specification |
Application: Power, Electronic;
Phase: Three;
Core: Shell-type Transformer;
Cooling Method: Air Natural (an);
Winding Type: Auto-transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer, Power System;
Frequency Characteristics: High Frequency;
Shape of Core: EI;
Brand: Gangwan;
Voltage: 11-33kv;
Frequency: 50/60Hz;
Power Rating: 1500kVA;
Cooling Type: Onan/Onaf;
Tap Changer: off-Circuit Tap Changer (Octc);
Insulation Level: High-Grade Insulation;
Standard: IEC, ANSI, ISO, etc.;
Applications: Urban Infrastructure, Industrial Plants, Renewable;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 50mva;
Vector Group: Ynd11;
Hv: 66-220kv;
LV: 6-35kv;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou Electric;
High Voltage: 10kv;
Low Voltage: 0.4kv/0.415kv;
Rated Capacity: 30-2500kVA;
Connection Group: Dyn11/Yyn0;
Frequency: 50Hz/60Hz;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 1.3-0.55%;
Ambient Temperature: 40℃ -+ 40℃;
|
Application: Power;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou Electric;
High Voltage: 11kv/12kv/13.2kv/13.8kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-300 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40℃ -+ 40℃;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
Rated Capacity: 100-3500kVA;
High Voltage: 11kv 6kv 6.6kv 15kv 20kv;
Low Voltage: 0.4kv/0.415kv;
Ambient Temperature: 40℃ -+ 40℃;
No-Load Loss: 0.17-3.24kw;
Load Loss: 0.71-17.7kw;
Frequency: 50Hz/60Hz;
Connection Group: Dyn11 Yyn0;
|