Basic Info.
Structure Design
Flange Type
Pressure Range
Atmospheric pressure
Working Temperature
-25 to +240 C
Electric Interface
1/2NPT or M20*1.5
Process Connection
1/4NPT or 1/2NPT
Flange Joint
M20*1.5" External Thread 1/2-14NPT Taper Pipe Th
Intrinsically Safe
Ia II C T6
Transport Package
Export Package
Product Description
Flange liquid level transmitter is an on-site transmitter that is mounted directly on a pipe or vessel. Since the isolating diaphragm is directly in contact with the liquid medium, it is not necessary to take out the pressure guiding tube on the positive pressure side, so that the liquid level, pressure and density of the medium such as high temperature, high viscosity, easy crystallization, easy precipitation and strong corrosion can be measured, and then It is converted to 4~20mA.DC signal output.
Max ref accuracy:0.1%calibration range
Stability:6months,±0.1%URL
Static pressure:13.79Mpa
Isolation diaphragm:316Lstainlesssteel,HC,Monel,tantalum
stability:6months,±0.1%URL
Current output:4 - 20 mA 2 wires Har t Protocol
Power supply:24VDC
Damping time constant:time constant is adjustable, in 0.1 second increments from a minimum to 16 seconds
Model selection guide
Name | Specification code | Explanation |
3051LT | | Level transmitter |
| 4 | 635-3810 mmH2O |
5 | 3175-19090 mmH2O |
6 | 11730-70380 mmH2O |
Output Signal | E | 4-20mA |
S | 4-20mA, HART Protocol Communication |
Installation flange | H5 | 2" (DN50) |
A8 | 3"(DN80) |
B10 | 4"(DN100) |
Wetted Parts Material | | Flange/Joint | Exhaust/Drain Valve | Diaphragm |
22 | Stainless Steel | Stainless Steel | 316L Stainless Steel |
23 | Hastelloy C-276 |
24 | Tantalum |
Display Header (optional) | M2 | Linear Pointer Header (0~100% scale) |
M3 | Square Root Instruction Header(0~100% scale) |
M4 | LCD Header( linear display) |
Process Flange | D1 | The liquid discharge / exhaust at the side top |
D2 | The liquid discharge / exhaust at the side bottom |
Instrument output 4 ~ 20mA standard DC signal, supply display, multi-point inspection, recording, control, adjustment and other instruments or PLC, DCS, FCS system to achieve automatic recording and adjustment of the level. The contact between the instrument and the material has good corrosion resistance and is suitable for continuous monitoring of liquid level, material level, oil-water interface and foam interface in metallurgy, chemical industry, environmental protection, power station, papermaking, pharmaceutical, printing and dyeing, food, municipal and other industries.
Address:
No 3 Hengshan Road, Yantai, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9000
Company Introduction:
Scope of business
Instrument and meter, mechanical spare parts, mechanical and electrical products, electronic products, chemical