SPECIFICATIONS |
|||||||||
OUTPUT |
|
||||||||
Model |
SP-75-5 |
SP-75-7.5 |
SP-75-12 |
SP-75-13.5 |
SP-75-15 |
SP-75-24 |
SP-75-27 |
SP-75-48 |
|
DC Voltage |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
|
Rated Current |
15A |
10A |
6.3A |
5.6A |
5A |
3.2A |
2.8A |
1.6A |
|
Current Range |
0-15A |
0-10A |
0-6.3A |
0-5.6A |
0-5A |
0-3.2A |
0-2.8A |
0-1.6A |
|
Rated Power |
75W |
75W |
75.6W |
75.6W |
75W |
76.8W |
75.6W |
76.8W |
|
Ripple & Noise |
80mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
80mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
DC Adjustment Range |
-5%,+10% |
-5%,+10% |
-5%,+10% |
-5%,+10% |
-5%,+10% |
-5%,+10% |
-5%,+10% |
-5%,+10% |
|
Voltage Tolerance |
±2% |
±2% |
±2% |
±2% |
±2% |
±1% |
±1% |
±1% |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load Regulation |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup, Rise, Hold Up Time |
800ms,60ms,36ms at full load |
||||||||
|
|
||||||||
INPUT |
|
||||||||
Voltage Range |
85~264 VAC 47-63Hz;120~370VDC |
||||||||
AC Current |
1.3A/115 VAC 0.7A/230VAC |
||||||||
Power Factor |
PF>0.93/230VAC,PF>0.96/115VAC at full load |
||||||||
Efficiency |
76% |
79% |
81% |
82% |
82% |
83% |
83% |
83% |
|
Inrush Current |
Cold start 45A/230VAC |
||||||||
Leakage Current |
<2mA/240VAC |
||||||||
PROTECTION |
|
||||||||
Over Load |
105%-150% rated output power |
||||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||||||||
Over Voltage |
115%~135% |
||||||||
Protection type: Shut down o/p voltage, re-power on to recover |
|||||||||
Function |
CN3:4~10VDC POWER OFF, <0~0.8VDC POWER ON |
||||||||
ENVIRONMENT |
|
||||||||
Working Temp. Humidity |
-10ºC~+60ºC; 20%~90% RH non-condensing |
||||||||
Storage Temp. Humidity |
-20ºC~+85ºC; 10%~95% RH |
||||||||
Temp. Coefficient |
±0.05%/ºC(0~50ºC) |
||||||||
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
||||||||
SAFETY |
|
||||||||
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC |
||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25ºC/70% RH |
||||||||
STANDARD |
|
||||||||
Safety Standard |
Design refer to UL60950-1,TUV EN60950 |
||||||||
EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,light industry level, criteria A |
||||||||
|
|
||||||||
OTHERS |
|
||||||||
Dimension |
179*99*33mm(L*W*H) |
||||||||
Weight |
0.58Kg/pc;20pcs/12kg/0.64CUFT |
NOTE:
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.