1. Technical Specifications
Vacuum Tube Furnace | VTF-1200T | VTF -1400T | VTF -1700T |
Max temperature | 1200C | 1400C | 1700C |
Working temperature | ≤1100C | ≤1300C | ≤1600C |
Heating rate | 0-20C/min |
Temperature accuracy | ± 1C |
Temperature control | 51segments programmable and PID auto control |
Max. Vacuum | - 0.08Mpa |
Furnace chamber | Ceramic fiber |
Furnace structure | Double shell with fan cooling |
Thermocouple | K type | S type | B type |
Heating elements | Fe-Cr-Al-Mo wire | Sic heater | MoSi2 heater |
Voltage | 220V/380V 50Hz/60Hz |
Standard type | QSH-VTF-1200T | QSH-VTF-1400T | QSH-VTF-1700T |
Tube size | Φ40×300mm Φ40×450mm Φ60×300mm Φ60×450mm Φ80×300mm Φ80×450mm Φ100×300mm Φ100×450mm Φ120×300mm Φ120×450mm |
3.the temperature profile that we would like to set.
4.Heating elements
Working temperature | Heating elements | Characteristics |
W T≤1200C | Fe-Cr-Al-Mo wire | Compared with the ordinary iron chromium aluminum wire resistance, higher temperature and more durable |
W T≤1400C | SiC heater | Using high temperature, anti-oxidation, corrosion resistance, long life, small deformation, easy installation and maintenance. |
W T≤1750C | MoSi2 heater | Suitable for ultra high temperature heating, long service life, high calorific value and economic price |
5. Trouble shooting for typical Problems
Problems | Reason | Solution |
Open Power Lock, no power indication | Fuse (4A) in control panel is broken | Check control panel, and replace fuse |
Green Power indictor is off, but Red open circuit indicator is On | Fuse ( 50A) in main power circuit is broken | Open the cover of front panel and replace the fuse |
No current shows in meter , but has Max. Voltage | Heating element broken | Find broken heating rod, and replace it |
Controller display panel SV shows" OraL" | Thermal Couples broken | Replace Thermal couples ( B type ) |
Controller display panel SV shows" HI AL" | Furnace temperature > 1700C, Protection from Alarm | Cool furnace down, and find reason why temperature is so high ( program setting may be wrong) |
Power and heating element are OK, but furnace can't be controlled by program. | Controller or related circuit may be damaged | Heck controller. |
Program running, but furnace can not be heated, or real temperature is far behind the setting value | oPL or oPH value is too low due to local voltage lower or frenquency different | Incraese "oPL" and "oPH" value till current meter shows " 120 A - 140 A", and program runs smoothly |
During heating below 300C, the temperature value ( PV) is not stable, and doesn't match with setting program (SV) | It is normal because the furnace comes with a high temperature thermocouple, which is not sensitive at temperature below 300C | Don't worry. Let the furnace heat to 300C, then thermocouple will function stably with program. If the PV value at 300C is still less than that of SV, you may need to increase OPL value a little. |
1, Muffle furnaces / Box furnaces / Chamber furnaces / Lab furnaces
2,Vacuum tube furnaces / Multi zones tube furnaces
3,Atmosphere furnaces / Vacuum Furnaces
4,Silicon Carbide Heating Elements
5,Molybdenum Disilicide Heating Elements
6,Other Furnaces related products
FAQ:
Are you a manufacturer?
Yes, we have been manufacturing different models of furnaces for years.
What quality standard you have acquired?
All our products are CE approval.
Do you have your own R&D team?
Yes, we have R&D department, a group of retired personnels and highly educated expertise staff.
They will make the products perfect and design your requirements for free.
What temperature you can make?
Usually the Max.temperature include 3 levels: 1200C/ 1400C/ 1700C
The heating elements we are using are:
Max. Temperature | Heating Elements |
1200C | Fe-Cr-Al-Mo wire |
1400C | Quality SiC heater |
1700C | MoSi2 heating element |
What information should i let you know if i want to get a quotation?
It's best for you to offer us the chamber size,temperature,etc.
How many days will the goods be finished?
Usually stocks are available.If stock finish,the standard sizes take one week to finish.
For non-standard sizes,30 working days after receiving the down payment.
Do you inspect the finished products?
Yes,each step of production and finished products will be carried out inspection by QC department before shipping.
How do you ship the products?
By sea;
By plane;
By couriers, DHL, TNT, Fedex, UPS, etc.
Address:
Room 303 Building 7 Number 3601 Dongfang Road Pudong New Area Shanghai, Shanghai, China
Business Type:
Manufacturer/Factory
Business Range:
Consumer Electronics, Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery, Metallurgy, Mineral & Energy, Tools & Hardware
Management System Certification:
ISO 9001
Company Introduction:
Shanghai Alarge Furnace Co., Ltd. Is a seasoned enterprise specializing in electric furnace equipment, integrating R&D, production, sales, and service. The company has been established for over a decade. The main large-scale experimental production equipment includes medium frequency melting furnace, air pressure sintering furnace, vacuum tungsten wire furnace, vacuum carbon tube furnace, vacuum hot pressing furnace, etc. Small and medium-sized experimental equipment includes muffle furnace, atmosphere furnace, small and medium-sized vacuum furnace, vacuum tube furnace, multi-temperature zone tube furnace and rotary tube furnace, etc.
Products are widely exported to Europe, America, Southeast Asia, the Middle East, and occupy a certain share in the domestic market. The company focuses on technology research and development, has a number of intellectual property rights, and continues to promote technological innovation, which is recognized by major scientific research units, university research institutes and high-tech material manufacturers.