SRU-400H (02312NEU: SRU-400H, Service and Router Unit 400H, 14*10GE(SFP+), 10*GE Copper, 1*USB2.0)
Overview
Table 6-30 Basic information about the SRU-400HItem | Details |
---|
Description | SRU-400H, Service and Router Unit 400H, 14*10GE(SFP+), 10*GE Copper, 1*USB2.0 |
Part Number | 02312NEU |
Model | SRU-400H |
Silkscreen | SRU-400H |
Appearance
Figure 6-15 Appearance of the SRU-400H
Version Mapping
Table 6-31 Mappings between SRU-400H and product modelsProduct | Product Model | First Supported Version | Last Supported Version | Unsupported Version | Limitations |
---|
AR6200 | AR6280 (02115641) | V300R019C00 | - | - | - |
AR6200 | AR6280 (02115641-001) | V300R021C10 | - | - | - |
AR6300 | AR6300 (02115640) | V300R019C00 | - | - | - |
AR6300 | AR6300-S (02352VEL) | V300R019C00 | - | - | - |
AR6300 | AR6300-S (02352VEL-001) | V300R022C00 | - | - | - |
Indicators and Buttons
Figure 6-16 Indicators and buttons on the SRU-400H
1. SYS indicator | 2. ACT (active/standby status) indicator | 3. iNET indicator |
4. CTRL indicator | 5 and 6. 10GE optical interface indicators - 5: ACT indicator, yellow
- 6: LINK indicator, green
| 7. ACT (USB) indicator |
8 and 9. GE electrical interface indicators - 8: ACT indicator, yellow
- 9: LINK indicator, green
| 10. RESET button | - |
Table 6-32 Indicators on the SRU-400HSilkscreen | Name | Color | Status | Description |
---|
SYS | SYS indicator | Green | Slow blinking | The system is running properly. |
Green | Fast blinking | The system is being powered on or restarting. |
Red | Steady on | A fault that affects services has occurred and cannot be rectified automatically. The fault needs to be rectified manually. |
- | Off | The system software is not running or is resetting. |
ACT | ACT (active/standby status indicator) indicator | Green | Steady on | The SRU is in active state. |
- | Off | The SRU is in standby state. |
iNET | iNET indicator | Green | Steady on | The network service has been established. |
- | Off | The network service is unavailable. |
CTRL | CTRL indicator | Green | Steady on | The device has been managed by the controller. |
Green | Blinking | The plug-and-play deployment is ongoing by the registration query center. |
CTRL | CTRL indicator | - | Off | The device has not been managed by the controller. |
- | 10GE optical interface indicators | Green (Link) | Steady on | A link has been established on the interface. |
Green (Link) | Off | No link is established. |
Yellow (ACT) | Blinking | Data is being transmitted or received on the interface. |
Yellow (ACT) | Off | No data is being transmitted or received on the interface. |
ACT | ACT (USB) indicator | Green | Steady on | The system has been upgraded or configured using a USB flash drive. |
Green | Blinking | The system is being upgraded or configured using a USB flash drive. |
Red | Steady on | The system fails to be upgraded or configured using a USB flash drive. |
- | Off | No USB flash drive is connected, the USB interface has failed, or the indicator has failed. |
- | GE electrical interface indicators | Green (Link) | Steady on | A link has been established on the interface. |
Green (Link) | Off | No link is established. |
Yellow (ACT) | Blinking | Data is being transmitted or received on the interface. |
Yellow (ACT) | Off | No data is being transmitted or received on the interface. |
Table 6-33 Buttons on the SRU-400HSilkscreen | Name | Description |
---|
RESET | RESET button | This button is used to reset the router. - In an empty configuration scenario, ensure that the router has no console port input, and has no user login routers. If the Reset button is pressed and held for at least 5 seconds, you will access the registration query center of Huawei devices and obtain the cloud management platform address of routers for plug-and-play deployment.
- In the configured scenario, hold down the button for at least 5 seconds to restore the factory settings.
- To reset the router, hold down the button for less than 5 seconds.
Resetting the router will interrupt services. Exercise caution when deciding to press this button. |
Ports
Figure 6-17 Ports on the SRU-400H
1. One MEth interface NOTE:MEth interface is the management network port on a device. It can implement web-based network management and email-based deployment. | 2. WAN interfaces: fourteen 10GE optical interfaces NOTE:GE optical modules can be inserted into these fourteen optical interfaces. All 10GE WAN interfaces can be configured as LAN interfaces. | 3. USB 2.0 interface |
4. WAN interfaces: ten GE electrical interfaces NOTE:All GE WAN interfaces can be configured as LAN interfaces. | 5. Console interface | - |
Table 6-34 Ports on the SRU-400HPort | Connector Type | Description | Available Components |
---|
Console interface | RJ45 | The console interface of a router can connect to an operation terminal for onsite configuration. - Standards compliance: RS232
- Working mode: Full-duplex Universal Asynchronous Receiver/Transmitter (UART)
- Data equipment type: Data Circuit-terminating Equipment (DCE)
| Console cable |
USB 2.0 interface | USB 2.0 Type A | A USB interface provides up to 480 Mbit/s upload and download rates. - Standards compliance: USB2.0
- Working mode: Host
| USB 2.0 standard USB flash drive |
GE electrical interface | RJ45 | A GE electrical interface (10/100/1000 Mbit/s auto-sensing) transmits and receives services at 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s. - Standards compliance: IEEE802.3, IEEE802.3u, IEEE802.3ab
- Working mode: Full-duplex (10/100/1000 Mbit/s auto-sensing)
- Maximum transmission distance: 100 m
| Ethernet cable |
10GE optical interface | LC/PC | The 10GE optical interfaces (1/10 Gbit/s auto-sensing) can work in GE mode and can transmit and receive service traffic at 1 Gbit/s or 10 Gbit/s. - Optical interface attributes: The optical interface attributes vary depending on the optical module used.
- Standards compliance: IEEE 802.3ae
NOTE:The GE SFP Copper module supports only the GE 1000 Mbit/s rate mode and does not support the 100 Mbit/s or 10 Mbit/s rate mode. The optical/electrical module is used only to connect to GE electrical ports. | Optical module The following optical modules are supported: GE eSFP Optical Modules 10GE SFP+ Optical Modules GE SFP Copper Modules GPON&EPON Optical Modules |
Functions and Features
Table 6-35 Functions and features of the SRU-400HFunctions and Features | Description |
---|
Overview | A Service and Router Unit (SRU) integrates the control and management functions and provides the control plane, management plane, and switching plane for the system. - Control plane: provides functions such as protocol processing, service processing, route calculation, forwarding control, service scheduling, traffic statistics collection, and system security.
- Management plane: provides functions such as system monitoring, environment monitoring, log and alarm processing, system software loading, and system upgrade.
- Switching plane: provides high-speed, non-blocking data channels for service switching between service modules.
|
Basic function | Stores system configuration data, startup files, upgrade software, and system running logs. |
Voice function | Not supported |
Control module | Provides the control plane and management plane to implement functions such as protocol processing, route calculation, forwarding control, system management, and system security. |
Switching module | Acts as the service switching plane and provides high-speed channels for service switching functions. |
Power module | Provides power for other modules of the SRU. |
Clock module | Not supported |
Technical Specifications
Table 6-36 Technical specifications of the SRU-400HItem | Specification |
---|
Card type | EXSIC |
Dimensions without packaging (H x W x D) [mm(in.)] | 40.14 mm x 402.8 mm x 270.85 mm (1.58 in. x 15.86 in. x 10.66 in.) |
Weight without packaging [kg(lb)] | 3.3 kg (7.27 lb) |
Typical power consumption [W] | 73.6 W |
Maximum power consumption [W] | 92 W |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
CPU | 16-core, 2.26 GHz |
Memory | 8 GB |
NAND Flash | 2 GB To view the available memory size, run the dir command. |
Hard disk | Not supported |
DSP slot | Not supported |
Console management port | RJ45 |
Hot swapping | Supported |
Address:
Building 2, No. 1 Shangdi Information Road, Haidian District, Beijing, China
Business Type:
Manufacturer/Factory
Business Range:
Computer Products, Construction & Decoration, Consumer Electronics, Security & Protection, Service
Company Introduction:
Beijing Zhongwang Shujian Technology Co., Ltd. Is a service limited integration company that sells network equipment and software.
We mainly sell switch equipment, network switches, data switches, routers, routing gateways, hardware firewalls, WEB firewalls, servers, storage servers, UPS power supplies, communication power supplies, Huawei Cloud, optical access equipment, wireless APs, network management software, and other products.
The company has collaborated with telecommunications equipment manufacturers such as Huawei, H3C, Ruijie, Shenxin, and Tianrongxin, winning the trust of a large number of users. Provide customers with network park design and planning, data center system construction, wireless factory coverage, equipment installation, debugging, maintenance, etc.
Openness, cooperation, and win-win are the cornerstone of China Open Data Construction Company′s service to various industries. In the future, we will continue to uphold the values of innovation, responsibility, and service first, guided by customer needs, and continuously optimize our products and services. We will continue to expand our market coverage, expand into new business areas, and enhance our company′s influence in the industry. At the same time, we will actively embrace new technologies, continuously enhance our core competitiveness, and lay a solid foundation for achieving sustained growth and long-term development.
Together, there is a future.