Basic Info.
Model NO.
S6730S-H24X6C-A
Communication Mode
Full-Duplex & Half-Duplex
Transmission Rate
10/1000/10000/100000/100000Mbps
Specification
442.0mm× 446.0mm× 43.6mm
Product Description
S6730S-H24X6C-A(02353HVK/02353HVK-001/02353HVK-003/02353HVK-004)
Software Companionship
Table 4-263 lists the matching relationships between the S6730S-H24X6C-A and the software versions.Table 4-263 Supporting relationshipsFigure 4-104 S6730S-H24X6C-A10GE SFP+ Ethernet optical interfaceThe 10GE SFP+ Ethernet optical interface supports 1000M adaptation and is mainly used for receiving and transmitting Gigabit and 10000M services. Table 4-264 lists the interface attributes of a 10GE SFP+ Ethernet optical interface.Table 4-264 10GE SFP+ Ethernet interface attributes40GE/100GE QSFP28 Ethernet optical interfaceThe 40GE/100GE QSFP28 Ethernet optical interface is used for sending and receiving 40GE/100GE Ethernet optical interface services. Table 4-265 lists the interface attributes of the QSFP28 Ethernet optical interface.Table 4-265 QSFP28 Ethernet Optical Interface AttributesConsole interfaceThe console interface is used to connect to the console and realize the on-site configuration function, and the console communication cable needs to be used. Table 4-266 lists the interface properties of the console interface when the device is powered on for the first time.Table 4-266 Console interface propertiesETH management interfaceThe ETH management interface is used to connect with the network port of the configuration terminal or network management workstation to build an on-site or remote configuration environment, and a network cable needs to be used. Under the BootLoad menu, you can select the ETH management interface to load the software version package, which is faster than the console interface. Table 4-267 lists the interface attributes of the ETH management interface.Table 4-267 ETH interface attributesV200R012C00 and later versions, switches with ETH management interfaces support the first login to a device using the ETH port. If you have logged in to the device for the first time with the mode button (press and hold the mode button for 6s or more) and saved the configuration, the default configuration on the ETH port will be cleared, and you cannot log in for the first time using the ETH port. It is recommended to use the ETH port to log in to the device for the first time.USB interfaceThe USB port can be used with a USB flash drive, which can be used for deployment, transfer configuration files, upgrade files, etc. The USB flash drive must support the USB 2.0 standard.Due to the differences in the compatibility and drivers of USB flash drive models of different manufacturers, if the USB flash drive cannot be used, please try to replace the USB flash drive of the mainstream manufacturer, and the switch supports a USB flash drive with a capacity of no more than 128GB.The indicator identification and meaning of the S6730S-H24X6C-A device are the same as those of the S6730-H48X6C.When the device is powered by dual power supplies, the power supply to the host is 1+1 redundant backup mode, and pluggable AC and DC power modules can be configured on the same device at the same time.The S6730S-H24X6C-A device uses a pluggable fan module with a fan-forced heat dissipation type and a forward air flow and rear air outlet.The device in the diagram is only used as a schematic illustration of the direction of the airflow.Table 4-268 lists the specifications of the S6730S-H24X6C-A.Table 4-268 Specifications and parameters Equipment series | Device model | Imprint |
S6730S-H | S6730S-H24X6C-A | 02353HVK: Supported in V200R019C10 and later releases. 02353HVK-001: Supported V200R020C10 and later releases. 02353HVK-003: Supported for V200R021C10SPC500 and later releases (with V200R021C00SPC100 version requires V200R021SPH011 or its later patches). 02353HVK-004: Supported for V200R021C10SPC600 and later releases (with V200R021C00SPC100 version requires loading V200R021SPH013 or later patches). Illustrate: V200R021C01 version is not supported. |
Appearance structure
1 | 24 x 10GE SFP+ Ethernet optical interfaces Supported Modules and Cables: - GE Optical Transceivers
- GE-CWDM color optical module
- GE-DWDM color optical module
- GE Optoelectronic Modules
- 10GE SFP+ Optical Transceiver (OSXD22N00 not supported)
- 10GE-CWDM optical transceiver
- 10GE-DWDM optical transceiver
- 1m, 3m, 5m, 10m SFP+ high-speed cables
- 3m, 10m SFP+ AOC optical cable
- 0.5m, 1.5m SFP+ dedicated stacking cable (supported by the last 16 SFP+ interfaces, only for configuration-free stacking)
| 2 | 6 x 40GE/100GE QSFP28 Ethernet optical interfaces Supported Modules and Cables: - QSFP+ Optical Transceivers
- QSFP28 optical transceiver
- 1m, 3m, 5m QSFP+ High Speed Cables (QSFP+<->QSFP+)
- 10m QSFP+ AOC Optical Cable(QSFP+<->QSFP+)
- 1m QSFP28 High Speed Cable (QSFP28<->QSFP28)
- 10m QSFP28 AOC Optical Cable(QSFP28<->QSFP28)
- 2m QSFP28 Dedicated Stacking Cable (supported V200R020C10 and later)
Illustrate: When a QSFP28 Ethernet optical interface uses a QSFP28 optical module or a QSFP+ optical module, it cannot be split into four 10GE optical interfaces. The default rate of the QSFP28 Ethernet interface is 100GE. You can run the undo assign port-speed 100GE command (undo assign port-type 100GE in V200R020C00 and later versions) and restart the device to configure the interface to a 40GE interface. |
3 | Grounding screws Illustrate: Use a grounding cable. | 4 | SSD card slot Illustrate: Currently, it is a reserved slot and cannot be used. |
5 | 1 console interface | 6 | 1 ETH management interface |
7 | 1 USB port | 8 | 1 PNP button Notice: Press and hold (6s or more): Restore the factory configuration and reset the device. Short press: Reset the device. Resetting the device may interrupt the service and should be used with caution. |
9 | Fan module slot 1 Illustrate: Supported fan module: FAN-031A-B (Fan box (B, fan box panel side outlet)) | 10 | Fan module slot 2 Illustrate: Supported fan module: FAN-031A-B (Fan box (B, fan box panel side outlet)) |
11 | Fan module slot 3 Illustrate: Supported fan module: FAN-031A-B (Fan box (B, fan box panel side outlet)) | 12 | Fan module slot 4 Illustrate: Supported fan module: FAN-031A-B (Fan box (B, fan box panel side outlet)) |
13 | Power module slot 1 Illustrate: Supported Power Modules: - PAC600S12-CB (600W AC &240V DC Power Module)
- PAC600S12-EB (600W AC &240V DC Power Module)
- PAC600S12-DB (600W AC &240V DC power module) (supported V200R020C10 and later)
- PDC1000S12-DB (1000W DC Power Module)
| 14 | Power module slot 2 Illustrate: Supported Power Modules: - PAC600S12-CB (600W AC &240V DC Power Module)
- PAC600S12-EB (600W AC &240V DC Power Module)
- PAC600S12-DB (600W AC &240V DC power module) (supported V200R020C10 and later)
- PDC1000S12-DB (1000W DC Power Module)
|
API description
attribute | description |
Connector type | LC/PC |
Optical interface properties | It depends on the selected optical module |
Meets standards | IEEE802.3ae |
Working mode | 10GE/GE Adaptive |
attribute | description |
Connector type | MPO/LC |
Optical interface properties | It depends on the selected optical module |
Meets standards | IEEE802.3ba |
attribute | description |
Connector type | RJ45 |
Meets standards | RS-232 |
Working mode | UART(Universal Asynchronous Receiver/Transmitter) |
baud rate | 9600bit/s,19200bit/s,38400bit/s,57600bit/s,115200bit/s The default value is 9600 bit/s |
attribute | description |
Connector type | RJ45 |
Meets standards | IEEE802.3 |
Working mode | 10/100 Mbit/s self-adaptive |
Longest effective distance | 100m |
Indicator light description
Power configuration
Principle of heat dissipation
Specifications
specification | parameter |
Memory (RAM) | 4GB |
Flash | The physical space is 2 GB, and the actual available space can be viewed by running the display version command |
MTBF (years) | 62.27 |
Mean time to repair MTTR (hours) | 2 |
Availability | Greater than 0.99999 |
Specifications for lightning protection at the business port | ON |
Lightning protection specifications of the power port | - Configure AC power module: differential mode ± 6kV, common mode ± 6kV
- Configure DC power module: differential mode ± 2kV, common mode ± 4kV
|
Dimensions (W×D×H) | - Basic dimensions (depth is the distance excluding the protruding structural parts of the front and rear panels): 442.0mm× 420.0mm×43.6mm
- Maximum dimensions (depth is the maximum distance from the port protruding on the front panel to the handle of the rear panel module): 442.0mm× 446.0mm× 43.6mm
|
Weight (including packaging materials) | 9.84kg |
Stacking ports | - Any 10GE SFP+ interface (up to 16 physical interfaces)
- Any 40GE/100GE QSFP28 interface (up to 6 physical interfaces)
|
RTC | In the tank |
RPS | Not supported |
PoE | Not supported |
Rated voltage range | - AC input: 100V AC~240V AC; 50/60Hz
- High voltage DC input: 240V DC
- :-48V DC~-60V DC
|
| - :90V AC~290V AC;45~65
- :190V DC~290V DC
- :-38.4V DC~-72V DC
|
(100% ,) | 254 |
(30% , ATIS ) | 149 |
| -5°C~+45°C(0m~1800m) : 1800m~5000m,220m,1°C. 0°C . QSFP-100G-ER4,-5°C~40°C. |
| -40°C~+70°C |
(27°C,) | 65dB(A) |
| 5%RH~95%RH, |
| 0m~5000m |
| |
| 02353HVK 02353HVK-001 02353HVK-003 02353HVK-004 |
Address:
Building 2, No. 1 Shangdi Information Road, Haidian District, Beijing, China
Business Type:
Manufacturer/Factory
Business Range:
Computer Products, Construction & Decoration, Consumer Electronics, Security & Protection, Service
Company Introduction:
Beijing Zhongwang Shujian Technology Co., Ltd. Is a service limited integration company that sells network equipment and software.
We mainly sell switch equipment, network switches, data switches, routers, routing gateways, hardware firewalls, WEB firewalls, servers, storage servers, UPS power supplies, communication power supplies, Huawei Cloud, optical access equipment, wireless APs, network management software, and other products.
The company has collaborated with telecommunications equipment manufacturers such as Huawei, H3C, Ruijie, Shenxin, and Tianrongxin, winning the trust of a large number of users. Provide customers with network park design and planning, data center system construction, wireless factory coverage, equipment installation, debugging, maintenance, etc.
Openness, cooperation, and win-win are the cornerstone of China Open Data Construction Company′s service to various industries. In the future, we will continue to uphold the values of innovation, responsibility, and service first, guided by customer needs, and continuously optimize our products and services. We will continue to expand our market coverage, expand into new business areas, and enhance our company′s influence in the industry. At the same time, we will actively embrace new technologies, continuously enhance our core competitiveness, and lay a solid foundation for achieving sustained growth and long-term development.
Together, there is a future.