Product Introduction
Quick details.
Place of Origin: Zhejiang, China (Mainland)
Brand Name: Mseed
Model Number:MSM7C 250H
Rated current(A):100,125, 140, 160, 180, 200, 225, 250
Frame Current(In A):250
Rated voltage:AC400
flash-over distance(mm):≤50
Safety: 3C CE
Overview
M7C series residual current operated circuit breaker mainly used in three phase four wire circuit with AC 50Hz or 60Hz, rated voltage 440V, rated current to 800; except the protection of overload or short-circuit, it also has the protection of residual current , over voltage, under voltage, the phase-lacking, faulted neutral line(optional) and so on.The product with high level of performance is easy to use, and it can be used to display the current voltage, current, residual current, trip reason and phase intuitively.You can choose to have a RS485 communication interface, transfer of circuit breaker opening or closing state, the trip analysis, the voltage and current of each phase and the residual current circuit breaker's data; also can remotely set the protection action value and action time,can enable or disable the various protection functions.
All technical indexes are in conformity with GB14048.2-2008,GB6829-2008,Q/GDW11196-2014,Q/GDW11020-2013,CCC;and have passed the authoritative testing by Chinese EPRI of conventional function, residual current and special environment action characteristics, lightning protection module, communication function, scholte wave functions and technical parameters .
Functions
1. High-performance single-chip control program, and advanced LED digital display. Accurate action and High precision. It can be displayed digit alphanumeric.
2. Limit short-circuit breaking capacity can be up to lcu 85KA.
It has High breaking capacity, small volume, nice appearance, short flash-over distance.
3. Our product has won state invention patent such as design and other utility model patents.
4. It has Anti-interference ability. It adopts advanced anti-lightning residual voltage circuit and high strength transient protective device, resists lighting induction effectively and eliminates all interference.
5. The overload, overcurrent, undervoltage, residual current, short circuit, grounding protection function and manual, automatic reclosing together, ensuring electricity environment, equipment and personal safety.
6. Network management and remote monitoring could be realized With RS485 communication interface and intelligent digital control technology; Also can transmit fault trip signal to the mobile phone of the electrical engineering on duty based on the needs of users.
7. With automatic and manual operation also can carry on the remote operation according to the user needs.
8. It can display the product trip reason and it is convenient for the accurate maintenance.
9. It can be used with smart meter, magnetic type ammeter, prepaid card device, and as the operating components of power outages, power supply.
10. In case of the accident caused by leakage with tripping function.
Parameters
Technical Parameters | 3P+N
MSM7C-250 | 3P+N
MSM7C-630 |
Frame Current(In A) | 250 | 630 |
Rated Current (In A) | 100,125,140,160,180,200,225,250 | 200,225,250,315,350,400,500,630 |
Phase sequence | 1 3 5 N |
Rated insulation voltage(Ui V) | 690 |
Rated Voltage (Ui V) | 400 |
Electric Clearance | >5.5mm |
Creepage Distance | >6.3mm |
Rated impulse withstand voltage(Uimp KV) | 8 |
Power Frequency Voltage-Withstand | 2500V/1min No breakdown and flashing |
Insulation Resistance | ≥2MΩ |
Flash-over distance(mm) | ≤50 | ≤100 |
Rated ultimate short-circuit breaking capacity(lcu kA AC400V) | 70 | 70 |
Rated ultimate breaking capacity operation(lcu kA AC400V) | 50 | 50 |
Rated residual operating current( l△n mA) | 50,100,200,300,500,800 |
Rated residual operating current( l△no mA) | 0.71△n |
Rated breaking time(s) | as a protection for partial circuit:≤2l△n hours≤0.2s, 5l△n hours,10l△n hours≤0.15s
as a protection for the whole circuit:≤2l△n hours≤0.3s, 5l△n hours,10l△n hours≤0.25s |
Not driving time limit(s) | as a protection for partial circuit:≤2l△n hours≤0.1s, 5l△n hours,10l△n hours≤0.06s
as a protection for the whole circuit:≤2l△n hours≤0.2s, 5l△n hours,10l△n hours≤0.15s |
Reclosing delay time(s) | 20~60s |
Class for shell protection | IP20 |
Voltage operation under voltage action value(V) | 168±5% |
Breaker operating cycle times (ten thousand times) | 1 | 0.5 |
Inverse time operation characteristics:
Current | Action time |
1.05In | >2h No Action |
1.3In | <1h Action |
1.5In | The whole time(s) | 15 | 30 | 60 | 120 | 240 | 480 |
2.0In | Action time(s) | 8.4 | 16.9 | 33.7 | 67.5 | 135 | 270 |
Why Choose Us
•Professional manufacturer with internationally standard production lines and a devoted
technical team.
•Strict test procedure with advanced test equipment
•Responsive and responsible service team.
•Door to door service when needed.
•Helpful and enthusiastic in developing the buyers' business.
•Treat your career as our career.
Contact Us
Welcome to contact us:
For sales or information inquiry, please contact us in the following ways:
Mob:+8613588948309
Tel: +86-577-55770369
Trade messenger: barbara ye
Website: http://www.made-in-china.com/showroom/mseedbarbara
http://www.made-in-china.com/showroom/mseedbarbara