Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Protection Grade: IP54;
Usage Environment: Indoor or Outdoor;
Insulation Cylinder Material: Insulating Silicone Rubber;
Rated Current: 630A-1250A;
Rate Frequency (Hz): 50Hz/60Hz;
Usage: High Voltage;
Operation Method: Manual Operation/Electric Operati;
Rated Voltage: 6kv-11kv;
Mechanical Life: 2 (10,000 Times);
Custom Processing: Yes;
Rated Opening Operating Voltage: AC220;
Rated Closing Operating Voltage: AC220;
Operating Voltage: 110V 220V;
Sell: The Whole Global;
Resistance: 90-120 Ohms;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Structure: MCB;
Poles Number: 1p-4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Place of Origin: Zhejiang, China;
Brand Name: Aoasis;
Model Number: Aond-63;
Product Name: DC MCB;
Pole: 1p 2p 3p 4p;
Rated Current: 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125A;
Rated Voltage: DC250V, DC500V, DC750V, DC1000V;
Mechanical Life: 20000 Times;
Ambient Temperature: -35ºC~ +70ºC;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection, Short circuit;
Standard: IEC 61009-1;
Pole: 4P, 2P;
Tripping curve: B,C,D;
Rated Current (in): 63A;
Mode: Electromagnetic;
Residual Current Type: A;
Residual Current (LΔn): 30mA,100mA,300mA;
Icn: 6KA,10KA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: residual current device types;
|