Specification |
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Coil Structure: Toroidal;
Secondary Output: 0-500mA/1A/5A/333mv;
Primary Input: 5A-10ka;
Operation Temp: - 25 to + 75c;
Accuracy: 0.5/1 Class;
Lead Wire: According to Customer Requirements;
Frequency: 50/60Hz;
Insulation Strength: 3kv;
Inner Diameter: 10~51mm;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Rated Secondary Current: 5A or 1A;
Ambient Temperature: -5ºC~+40ºC;
|
Application: Instrument, Metering;
Type: Voltage Transformer;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv, 7.2/30/60kv;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8;
Rated Secondary Current: 5A or 1A;
Ambient Temperature: -25ºC~+40ºC;
|
Application: Instrument, Metering;
Type: Voltage Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv, 7.2/30/60kv;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8;
Rated Secondary Current: 5A or 1A;
Ambient Temperature: -5ºC~+40ºC;
|
Application: Instrument, Metering;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv,7.2/30/60kv;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8;
Rated Secondary Current: 5A or 1A;
Ambient Temperature: -5ºC~+40ºC;
|