Sepcifications

  • Type Fire Alarm Host
  • Function Networked
  • Usage Fire, Smoke
  • Certification CE, ISO, CCC
  • Alarm Volume (within 1m) ≥90dB
  • Networking Mode Can
  • Wiring Mode Bus System
  • Transport Package Standard Export Cartons
  • Trademark Ansorl
  • Origin China
  • Product Name Addressable Fire Alarm Control Panel
  • Main Power Supply AC 220V±20%/50Hz or DC24V
  • Backup Power Supply DC24V Battery Bat12V/5ah
  • Ambient Temperature -10 to +55 Celsius Degree
  • Ambient Humidity ≤95% No Condensation
  • Loop Capacity 100 / 200 / 324 / 648 Points
  • Loop Extension up to 16 Loops (as-9108e)
  • Display 4.3" LCD Display
  • Mini-Printer Optional
  • USB Interfaces Yes
  • LED Indicators Yes
  • Control Buttons Yes
  • Network Can Bus Networkable
  • Standard En54-2 & En54-4
  • Application Office, Factory, Warehouse, Apartment, Hotel etc.

Product Description

1 to 16 Loops Fire Alarm Detection Control Panel System Description AS-MN3010 Series fire alarm control panel is a new generation of fire alarm control panel launched by Shenzhen Ansorl Technology Co., Ltd. In order to meet the engineering design demand, the control unit is provided with ...

Learn More

Fire Alarm System Comparison
Transaction Info
Price US$300.00 - 600.00 / Piece US$1.00 / Piece US$1.00 / Piece US$1.00 / Piece US$1.00 / Piece
Min Order 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece
Payment Terms T/T, Western Union, Small-amount payment, Money Gram, Cash, Alipay, Wechat Pay T/T, PayPal, Western Union T/T, PayPal, Western Union T/T, PayPal, Western Union T/T, PayPal, Western Union
Quality Control
Product Certification CE, ISO, CCC En En En En
Management System Certification Others - - - -
Trade Capacity
Export Markets South America, Eastern Europe, Southeast Asia, Africa, Mid East, Oceania North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East North America, South America, Eastern Europe, Southeast Asia, Africa, Mid East
Annual Export Revenue - - - - -
Business Model - - - - -
Average Lead Time Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: 1-3 months
Off Season Lead Time: within 15 workdays
Product Attributes
Specification
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: Can;
Wiring Mode: Bus System;
Product Name: Addressable Fire Alarm Control Panel;
Main Power Supply: AC 220V±20%/50Hz or DC24V;
Backup Power Supply: DC24V Battery Bat12V/5ah;
Ambient Temperature: -10 to +55 Celsius Degree;
Ambient Humidity: ≤95% No Condensation;
Loop Capacity: 100 / 200 / 324 / 648 Points;
Loop Extension: up to 16 Loops (as-9108e);
Display: 4.3" LCD Display;
Mini-Printer: Optional;
USB Interfaces: Yes;
LED Indicators: Yes;
Control Buttons: Yes;
Network: Can Bus Networkable;
Standard: En54-2 & En54-4;
Application: Office, Factory, Warehouse, Apartment, Hotel etc.;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4 or 8;
Number of Connected Devices Per Zone: 32;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4,8,16;
Number of Connected Devices Per Zone: 32;
Standby Battery Capacity (2xdc 12V): 7.2ah;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Number of Networked Panels: 4;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Personal, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4,8 or 16;
Number of Connected Devices Per Zone: 32;
Standby Battery Capacity (2xdc 12V): 7.2ah;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Rela: 2;
Ancillary Fault N/C Relay: 1;
Number of Networked Panels: 4;
Type: Fire Alarm Host;
Function: Networked;
Usage: Door, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Wired;
Wiring Mode: Sub-Line System;
Alarm Zone Circuits: 2,4,8 or 16;
Number of Connected Devices Per Zone: 32;
Standby Battery Capacity (2xdc 12V): 7.2ah;
Number of Programmable Output Relays: 2;
Ancillary Fire C/O Relay: 2;
Ancillary Fault N/C Relay: 1;
Number of Networked Panels: 4;
Supplier Name

Shenzhen Ansorl Technology Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier

Ningbo Ambest Electronics Co., Ltd.

Gold Member Audited Supplier