Specification |
Classification: Biological Diagnostics;
Type: Mixer Shaker;
Group: Owner;
Product Name: Mixer Shaker;
Size: 197X135X156mm;
Capacity: 3.4kg;
Time Range: 0sec ~99min59sec;
Power: 60W;
Mixing Motion: Orbital;
Run Mode: Touch Operation/Continuous;
Orbit: 3mm;
|
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor Extraction System;
Group: All;
Product Name: Nucleic Acid Extraction System;
Nucleic Acid Extraction Method: Paramagnetic Particle Method;
Sample Volume: 20-1000UL;
Sample Capacity: 96-Well;
Extraction Time: 15min-60min;
Magnetic Bead Recovery: ≥98%;
Operating Temperature: Rt-105ºC;
Shock Function: Yes;
Temperature Accuracy: 0.1ºC;
Sample Protection Function: Power on Self-Check, Power off Protection, High-Te;
Disinfection Method: UV Light;
Safety Door Design: The Instrument Is Suspended When The Safety Door I;
Operating System: Windows System;
Scanning: Optional;
Storage: >1000;
|
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor Extraction System;
Group: All;
Product Name: Nucleic Acid Extraction System;
Sample Capacity Screen: 10.1 Inch Touch;
Sample Volume: 20-1000;
Sample Capacity: 1-96;
Magnetic Bead Recovery: ≥98%;
Extraction Time: 15- 40 Minutes;
Extracting The Differece Between Holes: CV≤3%;
Consumption: 500W;
Operating Temperature: Rt-120 ºC;
Product Purity A260/A280: DNA≥1.7-2.0; Rna≥1.8-2.1;
Shock Mlixing: Adjustable Speed (1-3);
Reagent Type: Open System for Magnetic Bead Method;
Power Supply: AC100V-240V 50Hz/60Hz;
External Size(W*D"H): 770*530"540mm;
Gross Weight: 95kg;
|
Classification: Biological Diagnostics;
Type: Chemistry Analyzer;
Group: All;
Product Name: Auto Chemistry Analyzer;
Test Speed: 220t/H;
Analysis Method: End-Point, Fixed-Time, Rate, Turbidimetry;
Sample Positions: 49 Sample Positions, Including Calibration, Quali;
Reagent Positions: 56 Refrigerated Reagent Positions;
Sample Volume: 2UL ~70UL (0.1UL Stepping);
Reagent Volume: R1 & R2: 20UL ~350UL (1UL Stepping);
Sample & Reagent Probe: Liquid Level Sensor Function, Anti-Collision Func;
Probe Washing: Automatically Wash Interior and Exterior;
Reaction Time: 10 Minutes;
Cooling Function: 2ºC~8ºC Cooling for 24 Hours;
Temperature Control: 37ºC±0.1ºC, Real-Time Monitor;
Receiver: 8 Precision Photo Receivers;
Linear Range: 0.000~3.000ABS;
Computer System: Windows7/8/10, Lis System Available;
|
Classification: Biological Diagnostics;
Type: Elisa Microplate Reader;
Group: All;
Product Name: Elisa Microplate Reader;
Measurementchannel: Vertical 8 Optical Channels;;
Wavelength Range: 400-800 Nm;
Filter: Standard Four Wavelengths of 405, 450, 492, 630nm;;
Readingrange: 0.000-4.000 ABS;
Linearrange: 0.000-3.000 ABS;
Repeatability: CV≤1.0%;
Stability: ≤±0.003ABS;
Absorbanceaccuracy: Absorbance Value [0.0~1.0];
Wavelengthindicationerror: ≤±2nm;
Wavelengthrepeatability: ≤±1.5nm;
Sensitivity: ≥0.01 Mg/L;
Channeldifference: ≤0.02ABS;
Vibrationplatefunction: 3 Kinds of Vibration Platefunction , Adjustable 0~;
Display: 10.1-Inch Large Touch Screen;
|