Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: New Energy Combiner Box Measurement;
IP Rating: IP44;
Customized: Customized;
Rated Input: 10/15/20/25/30A;
Measuring Range: 0~+-30A;
Supply Voltage: DC +5.0V;
Output Voltage: 2.500+-2.0V;
Offset Voltage: @IP=0, T=25°c < +-10mv;
Power Consumption: 10mA;
Primary Through-Hole: D8.5+-0.15mm;
Plastic Material: PBT G30/G15, UL94-V0;
|
Type: Rogowski;
Output Signal Type: Digital Output;
Production Process: SemiConductor Integrated;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Soft Switch;
IP Rating: IP67;
Customized: Customized;
|
Type: Amplifier/Integrator/Converter/Conditioner;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Rated Output: 5V AC RMS,4V DC(True-RMS),4-20mA;
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 200MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 12V or 24V;
Rated Input: 10A-6000A;
Read Accuracy: 0.5% Typical at 1%(≥10A) to 120% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Current Sensor: Rogowski Coil Y-Fct, Nrc, Trc;
Installation Site: Power Distribution Box;
Output on 0A (Zero Drift): ≤5mv(Rated Outut ≥2.5V; Zero Drift<10mv);
Temperature Drift: 200ppm/ºC;
Operating Temperature: -20ºC to 70ºC;
|
Type: Amplifier/Integrator/Converter/Conditioner;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Rated Output: 5V AC RMS,4V DC(True-RMS),4-20mA;
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 200MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 12V or 24V;
Rated Input: 100A-6000A;
Read Accuracy: 0.5% Typical at 1%(≥10A) to 120% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Current Sensor: Rogowski Coil Y-Fct, Nrc, Trc;
Installation Site: Power Distribution Box;
Output on 0A (Zero Drift): ≤5mv(Rated Outut ≥2.5V; Zero Drift<10mv);
Temperature Drift: 200ppm/ºC;
Operating Temperature: -20ºC to 70ºC;
|
Type: Amplifier/Integrator/Converter/Conditioner;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Rated Output: 5V AC RMS,4V DC(True-RMS),4-20mA;
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 200MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 12V or 24V;
Rated Input: 100A-6000A;
Read Accuracy: 0.5% Typical at 1%(≥10A) to 120% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Current Sensor: Rogowski Coil Y-Fct, Nrc, Trc;
Installation Site: Power Distribution Box;
Output on 0A (Zero Drift): ≤5mv(Rated Outut ≥2.5V; Zero Drift<10mv);
Temperature Drift: 200ppm/ºC;
Operating Temperature: -20ºC to 70ºC;
|