Specification |
After-sales Service: 24-Hour Online Service;
Warranty: 3 Years;
Weight: 20.3kg;
Power Source: AC110V/AC220V±10%;
AC Current Output: 6*30A/3*60A/1*180A;
AC Voltage Output: 6*120V/3*240V;
Power: 6*450va/1*1000va;
AC Accuracy: 0.2%;
DC Current Output: 6*±10A;
DC Voltage Output: 6*±160V;
DC Accuracy: 0.5%;
Frequncy: DC--1000Hz;
Harmonic: 2–20 Times;
Digital Input: 8 *10-250VDC or Free Contact;
Digital Output: 4*AC(0.5A, 250V) / DC(0.5A, 60V);
Time Accuracy: ±1ms;
GPS Timing Accuracy: 10us;
PC Control: Available;
Auxiliary DC Supply: 110V/220V, Max 330va;
|
After-sales Service: Lifetime Technical Support,Online Service;
Warranty: 1 Year for Transformer Oil Bdv Tester;
Type: Transformer Oil Bdv Tester;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Fully Automatic;
Weight: 45kg;
Power Source: AC220V;
Oil Cylinder Position: Top;
Product Name: Transformer Oil Bdv Tester;
Test Standards: IEC156, Is6792, BS5874, ASTM D1816 , ASTM D877;
Application: Test Breakdown Voltage Value of Transformer Oil;
Output Voltage: AC 0V~80kv (100kv for Choice);
Rate of Voltage Rise: 0.5kv/S, 2kv/S, 3kv/S, 5kv/S± 5%;
Display 1: LCD Touch Screen;
Printer: Micro Printer, PC Connection;
Max. Test Times: 9;
Stir Time: 0~999s;
Wait Time: 0~999s;
Oil Temperature Measurement Range: 0°c to 70°c, or Better;
Power Supply: AC220V, 50Hz/60Hz(Support Customize);
|
After-sales Service: Lifetime Technical Support;
Warranty: 1 Year for Transformer Turns Ratio Meter;
Type: Transformer Turns Ratio Meter;
Accuracy Grade: 0.2/0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: Digital;
Control: Manual Control;
Weight: 7kg;
Power Source: AC220V;
Application: Turns Ratio and Group Vector Test of Transformer;
Test Standard: IEC76-1, IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Ratio Measurement Error: 1-10000 ± 0.2%Rdg;
Test Voltage: 0~80V, Frequency 50Hz;
Power Supply: AC220V ± 10%, 50Hz/60Hz;
Phase Measurement Error: 1 Degree;
|
After-sales Service: Lifetime Technical Support, Online Service;
Warranty: 1 Year for Transformer Turns Ratio Tester;
Type: Transformer TTR Tester;
Accuracy Grade: 0.5;
Display: Digital;
Control: Manual Control;
Weight: 22kg;
Power Source: 220V 50/60Hz( Support Customize 110V/127V);
Application: Turns Ratio and Group Vector Test of Transformer;
Test Standard: IEC76-1, IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Ratio Measurement Error: 1-10000 ± 0.2%Rdg;
Test Voltage: 0~80V, Frequency 50Hz;
Power Supply: AC220V ± 10%, 50Hz/60Hz;
Phase Measurement Error: 1 Degree;
|
Warranty: One Year;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Material Testing Machine;
Maxcapacity: 120n;
Accuracy Grade: 1;
Load Way: Mechanical Load;
Loading Method: Static Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC220V;
Usage: Plug and Socket Safety;
Power: 220V 50 Hz;
Control Device: PLC;
|