| Specification |
Type: Network Type;
Measuring Medium: Temperature;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1;
IP Rating: IP68;
Customized: Customized;
Temperature Range: -40ºC to 400ºC;
Minimum Span: 100ºC;
Reference Accuracy: ±0.5% Url;
Annual Stability: ≤±0.5% Url or 0.1ºC/Year;
Output Signal: 2-Wire 4-20mA DC;
Resistance Category-1: Hcp Type Resistor Category;
Resistance Category-2: Hcc Type Copper Resistor Category;
Platinum Resistance Measurement Range: -200~500°C;
Copper Resistance Measurement Range: -150~100°C;
Platinum Resistance Reaction Time: 30~90seconds;
Copper Resistance Reaction Time: <180seconds;
Nominal Pressure of Thermocouple: Related with Many Conditions;
Minimum Insertion Depth of Thermal Resis: Temperature Sensing Element Length + Outer Diamete;
Insulation Resistance Value at Room Temp: <100MΩ;
Mesurment Accuracy: 0.15±0.002|T|;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP20;
Customized: Customized;
Storage Humidity: 10 ~ 95% (No Condensation);
Operating Humidity: 10 ~ 90% (No Condensation);
Storage Temperature: -45 ~ +80 ºC;
Operating Temperature: -40 to +85 ° C;
Impact Resistance Voltage: 3kv, 1.2/50us (Peak Value);
Isolation Voltage: 2500VDC, 1 Minute, Leakage Current (1mA);
Isolation: Input / Output / Auxiliary Power Isolation;
Current Output: ≤ 450ω;
Load Capacity: Voltage Output: ≥ 2 kΩ;
Temperature Drift: 50ppm / ºC (Typical);
Power: <1W;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP20;
Customized: Customized;
Accuracy1: 0.2% (Relative to Temperature);
Input: Three-Wire, Four-Wire or Two-Wire Rtd Signal,;
Output: Standard Voltage or Current Signal. Can Also Be Us;
Response Time: ≤ 100ms;
Auxiliary Power: DC5V, 9V, 12V, 15V, 24V;
Power: <1W;
Temperature Drift -: 50ppm / ºC (Typical);
Load Capacity: Voltage Output: ≥ 2 kΩ;
Current Output: ≤ 450ω;
Isolation: Input / Output / Auxiliary Power Isolation;
|
Type: Network Type;
Site Display: Not Site Display;
Accuracy: 0.2;
Customized: Customized;
Input: 0-75mv/0-2.5V/0-5V/0-10V, etc;
Output: 0-75mv/0-2.5V/0-5V/0-10V, etc;
Power Supply: 5VDC/12VDC/15VDC/24VDC;
Temperature Range: -45~+85 Centigrade;
Isolation Method: Magnetoelectric Isolation;
Isolation Voltage: 3000VDC;
Package: SIP 12pin or DIN3 or DIN35 Rail-Mounted for Option;
Certificates: CE RoHS ISO9001;
Accuracy Level: 0.1 Level, 0.2 Level;
Lead Time: 3-4working Days;
Warranty: 2 Years;
Shipping Way: DHL /FedEx etc;
Delivery Time: 3-5 Working Days;
Payment Way: Paypal ,T/T, Wester Union;
Keywords: Signal Converter, Signal Transmtiter;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1;
IP Rating: IP20;
Customized: Customized;
Typical Applications: Ntc Thermistor Temperature Signal Measurement;
Typical Applications1: RS-485 Remote I/O, Data Acquisition;
Typical Applications2: Intelligent Building Control;
Typical Applications3: RS485 Bus Industrial Automation Control System;
Typical Applications4: Industrial Site Signal Isolation and Long-Distance;
Typical Applications5: Equipment Operation Monitoring;
Typical Applications6: Measurement of Sensor Signals;
Typical Applications7: Acquisition and Recording of Industrial Field Data;
Typical Applications8: Development of Medical and Industrial Control Prod;
|