Specification |
After-sales Service: Maintenance & Refund;
Warranty: 1 Year;
Accuracy: ±0.6-1%;
Main Application: Liquid, Gas, Steam;
Size: DN15 - 300, DN300 - 1000;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid, Gas, Steam;
Measurement Object: Closed Pipeline;
Connection Method: Flange, Clamping-on;
Flow Velocity Range: Steam: <4m/S to 70m/S; Liquid: 0.7m/S to 7m/S ;Ga;
Process Pressure: up to 4.0 MPa;
Process Temperature: -25deg.C to +350deg.C;
Power Supply: 24VDC, 12VDC, 3.6V Lithium Battery;
Output: 4-20mA/Pulse/RS485/;
Housing Material: Aluminum Alloy;
Body Material: SS304;
Humidity: 5% - 85% Rh;
Protection Level: IP 65 / IP 68;
|
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70ºC;
Medium Temperature2: PTFE-20~120ºC;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70ºC;
Medium Temperature2: PTFE-20~120ºC;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: ±0.6-1%;
Main Application: Water, Wastewater;
Size: DN100-500;
Sensor: Plug-in;
Application: Industrial Production;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Measurement Object: Open Channel;
Flow Rate Range: 0~10m/S;
Flow Rate Resolution: 0.001m/S;
Velocity Accuracy: 0.001m/S (When Velocity <= 5m/S);
Ultrasonic Level Range: 6.5m;
Ultrasonic Level Accuracy: 0.001m;
Ultrasonic Level Resolution: 0.0005m;
Hydrostatic Level Range: 0~10m;
Hydrostatic Level Accuracy: ±0.1%Fs;
Hydrostatic Level Resolution: 0.001m;
Temperature Range: -20~60ºC;
Install: Special Bracket;
Material: Metal, POM, Rubber;
Protection Class: IP68;
Powered by: DC12V/24V;
Power Consumption: <90mA During Measurement; <25mA During Sleep;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: ±0.6-1%;
Main Application: Water, Wastewater;
Size: DN100-500;
Sensor: Plug-in;
Application: Industrial Production;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Measurement Object: Open Channel;
Flow Rate Range: 0~10m/S;
Flow Rate Resolution: 0.001m/S;
Velocity Accuracy: 0.001m/S (When Velocity <= 5m/S);
Ultrasonic Level Range: 6.5m;
Ultrasonic Level Accuracy: 0.001m;
Ultrasonic Level Resolution: 0.0005m;
Hydrostatic Level Range: 0~10m;
Hydrostatic Level Accuracy: ±0.1%Fs;
Hydrostatic Level Resolution: 0.001m;
Temperature Range: -20~60ºC;
Install: Special Bracket;
Material: Metal, POM, Rubber;
Protection Class: IP68;
Powered by: DC12V/24V;
Power Consumption: <90mA During Measurement; <25mA During Sleep;
|