Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Cps;
Poles Number: 3,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Nominal Voltage: AC380V;
Level of Protection: IP65;
Operating Temperature: -25ºC~+60ºC;
Mechanical Life: More Than 100, 000 Times;
Speed: Fast Trip;
Arc-Extinguishing Medium: Air & Magnetic Blowout;
Structure: Modular Cps;
Poles Number: 3.4;
Type: Control and Protection Switch;
Function: Short-Circuit.Overload Phase Failure .Earth Leakag;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 1P+N;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: B, C, D;
Rated Current (in): 16A, 20A, 25A, 32A, 40A, 50A,63A;
Mode: Electronic;
Residual Current Type: A, Ac;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Icn: 6kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: mcb rcbo;
keywords2: rcbo breaker;
keywords3: rcbo circuit breaker;
|
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: B, C, D;
Rated Current (in): 16A, 20A, 25A, 32A, 40A, 50A,63A;
Mode: Electronic;
Residual Current Type: A, Ac;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Icn: 6kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: mcb rcbo;
keywords2: rcbo breaker;
keywords3: rcbo circuit breaker;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection, Short circuit;
Standard: IEC 61009-1;
Pole: 4P, 2P;
Tripping curve: B,C,D;
Rated Current (in): 63A;
Mode: Electromagnetic;
Residual Current Type: A;
Residual Current (LΔn): 30mA,100mA,300mA;
Icn: 6KA,10KA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: residual current device types;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: AFDD;
Poles Number: 1P+N;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Standard: IEC/En 62606 & IEC 61009-1;
Pole: 1P+N;
Tripping Curve: B, C, D;
Rated Current (in): 6A, 10A, 16A, 20A, 25A, 32A, 40A;
Residual Current Type: Type A, AC;
Residual Current (LΔn): 30mA, 100mA, 300mA;
Making Breaking Capacity (IΔm): 2, 000A;
Icn: 6kA;
Energy Limiting Class: 3;
keywords: afdd and rcd;
keywords2: afdd circuit breaker;
keywords3: arc detection device;
|