Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: SF6;
Installation: Fixed;
Structure: Lbs;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Indoor Load Breaker Switch;
Keywords: Indoor Load Breaker Switch;
Product Model: Fln36;
Rated Voltage: 10/12kv;
Rated Frequency: 50Hz;
Current Rating: 630A;
Rated Peak Withstand Current: 50ka;
4s Rated Short-Time Withstand Current: 20ka;
Rated Closing Current: 50ka;
Active Load Interrupting Current: 630A;
Closed-Loop Interrupting Current: 630A;
Cable Charging Interrupting Current: 10A;
Rated Operating Voltage (Electric): AC/DC 220V;
Rated Voltage of Shunt Tripper: AC/DC 220V;
MOQ: 1 Piece;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCCB;
Poles Number: 3p, 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 10A to 1250A;
Rated Operation Voltage: up to 690V;
Rated Insulation Voltage: up to 1000V;
Poles: 3p, 4p;
Frame Class: 125 Type, 160 Type, 250 Type, 630 Type, 800 Type;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3,4;
Type: Circuit Breaker;
Poles No: 3,4;
Ics (Ka): 18~25;
Automatic Tripping Device: Thermo-Magnetic;
Rated Insulation Voltage(V): 690;
Rated Voltage Ue(V): 400;
Rated Current (a): 50~800;
ICU (Ka): 25~35;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 10A to 1250A;
Rated Operation Voltage: up to 690V;
Rated Insulation Voltage: up to 1000V;
Poles: 3p,4p;
Frame Class: 125 Type,160 Type,250 Type,630 Type, 800 Type;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 10A to 1250A;
Rated Operation Voltage: up to 690V;
Rated Insulation Voltage: up to 1000V;
Poles: 3p,4p;
Frame Class: 125 Type,160 Type,250 Type,630 Type, 800 Type;
|