600A 100A 5A Split Core Transformer
US$4.50 - 6.90 / Piece
  • Recommend for you
  • What is Miniature Round Transformer (GWD-00021-4) Toroidal Core Current Transformer
  • What is 10A/4mA 40A 0.1V 5A Voltage Monitoring Current Transformer
  • What is 200A/5A 2.5va Current Measuring Toroidal Current Transformer

What is Split Current Transformer Clamp Current Transformer Current Transformer with IEC, ETL, ISO9001

About this Item
Details
Company Profile

Price

Purchase Qty. Reference FOB Price

100-1,999 Pieces US$6.90

2,000-4,999 Pieces US$4.70

5,000+ Pieces US$4.50

Sepcifications

  • Application Electronic, Instrument, Position Sensor, Lighting
  • Type Current Transformer
  • Phase Single
  • Operation Condition Indoor
  • Usage Protection, Measurement, Relay Prodtion HVAC
  • Winding Form Multilayer Honeycomb Type
  • Insulating Medium Common Insulating Materials
  • Installation Active Type
  • Magnetic Circuit Structure Single Stage Type
  • Voltage Transformation Principle Electromagnetic Type
  • Transport Package Export Standard Carton
  • Specification ETL, CE CB, ISO9001 approval
  • Trademark Grewin
  • Origin China
  • Accuracy Class: 0.5 1.0s Ratio : 3000:1
  • Protection 5 Times Protection, 10 Times Protecti
  • Split Core Current Transformer 0.333-3.53V Rated Secondary Output
  • Application 1 Current, Power, Energy, Monitoring Devices
  • Application 2 Power Factor Correction Devices.
  • Rated Load 1, 2.5, 5.0, 10, 30va
  • Highest Voltage for Equipment Um (RMS) 720 VAC
  • Frequency Range 50/60Hz
  • Rated Power-Frequency Withstand Voltage; 3, 000 VAC
  • Output Split Core CT Standard:IEC 60044-1
  • Name Current Probe
  • Product1 Split CT Transformer
  • Product2 ETL Current Probe Transformer
  • Product 3 600A 100A 5A Split Core CT

Product Description

The GREWIN SCCT series of split core ct style current sensors are designed for fast and easy installation.The split core design permits non-contactcurrent measurements through magnetic field induction without disconnecting cables or busbar circuits for CT installation. This method permits a safer, ...

Learn More

600A 100A 5A Split Core Transformer Comparison
Transaction Info
Price US$4.50 - 6.90 / Piece US$0.60 - 0.70 / Piece US$0.85 - 0.90 / Piece US$0.82 - 0.85 / Piece US$90.00 / Piece
Min Order 100 Pieces 1,000 Pieces 5,000 Pieces 5,000 Pieces 3 Pieces
Payment Terms LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram LC, T/T, PayPal, Western Union
Quality Control
Management System Certification - - - - -
Trade Capacity
Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Annual Export Revenue - - - - -
Business Model - - - - -
Average Lead Time Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Product Attributes
Specification
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Relay Prodtion HVAC;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy Class: 0.5 1.0s: Ratio : 3000:1;
Protection: 5 Times Protection, 10 Times Protecti;
Split Core Current Transformer: 0.333-3.53V Rated Secondary Output;
Application 1: Current, Power, Energy, Monitoring Devices;
Application 2: Power Factor Correction Devices.;
Rated Load: 1, 2.5, 5.0, 10, 30va;
Highest Voltage for Equipment Um (RMS): 720 VAC;
Frequency Range: 50/60Hz;
Rated Power-Frequency Withstand Voltage;: 3, 000 VAC;
Output Split Core CT: Standard:IEC 60044-1;
Name: Current Probe;
Product1: Split CT Transformer;
Product2: ETL Current Probe Transformer;
Product 3: 600A 100A 5A Split Core CT;
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: H-CT003A;
Current Ratio: 5(30)a/2.5mA;
Rate Current: 5A;
Max Primary Current: 30A;
Secondary Current: 2.5mA;
Turn Ratio: 1:2000;
Burden Resistance: 20 Ohm;
Accuracy: 0.1class;
Install Item: Pin/SMT/PCB;
Manufacturer: Jiaxing Haihan Electron Co.,Ltd;
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: H-CT003c;
Current Ratio: 5(40)a/5mA;
Rate Current: 5A;
Max Current: 60A;
Secondary Current: 5mA;
Coil Ratio: 1:1000;
Burden Resistance: 100 Ohm;
Accuracy: 0.2class;
Install Item: Pin/SMT/PCB;
Manufacturer: Jiaxing Haihan Electron Co.,Ltd;
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rate Current: 10A;
Max Current: 50A;
Secondary Current: 4mA;
Coil Ratio: 1:2500;
Burden Resistance: 100 Ohm;
Accuracy: 0.2class;
Install Item: Pin/SMT/PCB;
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Instruments;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Types: Current Transformer Clamp;
Ratio: 1000:1, 1000:5, 500:5;
Color: Gray or Blue;
Current Range: 0-1200A;
Output Signal: 0-5A or 0-5V;
Output Cable: 2.5m;
Diameter: 50mm;
Weight: 550g;
Size: 102.9mm X 219.6mm X 28mm;
Class: 0.1;
Supplier Name

Tianjin Grewin Technology Co., Ltd.

Diamond Member Audited Supplier

Jiaxing Haihan Electron Co., Ltd.

Diamond Member Audited Supplier

Jiaxing Haihan Electron Co., Ltd.

Diamond Member Audited Supplier

Jiaxing Haihan Electron Co., Ltd.

Diamond Member Audited Supplier

Beijing GFUVE Electronics Co., Ltd.

Diamond Member Audited Supplier