| Specification |
After-sales Service: Online Technical Support;
Warranty: 2 Year After-Sales Service;
Max Diameter of Workpiece: <500mm;
Type: Thrust Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.1;
Load Way: Mechanical Load;
Loading Method: Static Load;
Display: Digital;
Control: Manual Control;
Weight: 100g-100kg;
Power Source: AC220V;
Tensile Testing Range: 100g to 20kg;
Thrust Testing Range: 250g to 100kg;
Module Switching: Auto Rotation Module;
X-Axis/Y-Axis: Effective Stroke 100-500mm,Resolution 0.1μm;
Z-Axis Testing Min Positioning Height: <=1μm;
|
After-sales Service: Lifetime Technical Support,Online Service;
Warranty: 1 Year for Transformer Oil Bdv Tester;
Type: Transformer Oil Bdv Tester;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Fully Automatic;
Weight: 45kg;
Power Source: AC220V;
Oil Cylinder Position: Top;
Product Name: Transformer Oil Bdv Tester;
Test Standards: IEC156, Is6792, BS5874, ASTM D1816 , ASTM D877;
Application: Test Breakdown Voltage Value of Transformer Oil;
Output Voltage: AC 0V~80kv (100kv for Choice);
Rate of Voltage Rise: 0.5kv/S, 2kv/S, 3kv/S, 5kv/S± 5%;
Display 1: LCD Touch Screen;
Printer: Micro Printer, PC Connection;
Max. Test Times: 9;
Stir Time: 0~999s;
Wait Time: 0~999s;
Oil Temperature Measurement Range: 0°c to 70°c, or Better;
Power Supply: AC220V, 50Hz/60Hz(Support Customize);
|
After-sales Service: Lifetime Technical Support;
Warranty: 1 Year for Transformer Turns Ratio Meter;
Type: Transformer Turns Ratio Meter;
Accuracy Grade: 0.2/0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: Digital;
Control: Manual Control;
Weight: 7kg;
Power Source: AC220V;
Application: Turns Ratio and Group Vector Test of Transformer;
Test Standard: IEC76-1, IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Ratio Measurement Error: 1-10000 ± 0.2%Rdg;
Test Voltage: 0~80V, Frequency 50Hz;
Power Supply: AC220V ± 10%, 50Hz/60Hz;
Phase Measurement Error: 1 Degree;
|
After-sales Service: Lifetime Technical Support, Online Service;
Warranty: 1 Year for Transformer Turns Ratio Tester;
Type: Transformer TTR Tester;
Accuracy Grade: 0.5;
Display: Digital;
Control: Manual Control;
Weight: 22kg;
Power Source: 220V 50/60Hz( Support Customize 110V/127V);
Application: Turns Ratio and Group Vector Test of Transformer;
Test Standard: IEC76-1, IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Ratio Measurement Error: 1-10000 ± 0.2%Rdg;
Test Voltage: 0~80V, Frequency 50Hz;
Power Supply: AC220V ± 10%, 50Hz/60Hz;
Phase Measurement Error: 1 Degree;
|
Warranty: One Year;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Material Testing Machine;
Maxcapacity: 120n;
Accuracy Grade: 1;
Load Way: Mechanical Load;
Loading Method: Static Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC220V;
Usage: Plug and Socket Safety;
Power: 220V 50 Hz;
Control Device: PLC;
|