| Specification | 
                                                    
                                
                                    
                                                                                     After-sales Service: 1 Year; 
                                                                                     Principle: Ultrasonic; 
                                                                                     Range: 0-30m; 
                                                                                     Measurement Accuracy: ±1mm; 
                                                                                     Accuracy: 0.5%; 
                                                                                     Kind: Liquid Level Transmitter; 
                                                                                     Structure: All in One/Slipt; 
                                                                                     Warranty: 1 Year; 
                                                                                     Process Temperature: -20℃~80℃; 
                                                                                     Analog: 4-20mA; 
                                                                                     IP Grade: IP65; 
                                                                                     Display: LCD Display; 
                                                                                     Dead Zone: 0.25-0.8m; 
                                                                                     Supply Voltage: DC24V/AC220V,Lsp; 
                                                                             
                                 
                             | 
                                                    
                                
                                    
                                                                                     After-sales Service: Maintenance & Refund; 
                                                                                     Principle: Ultrasonic Non-Contact Measurement; 
                                                                                     Range: 0-30m; 
                                                                                     Measurement Accuracy: ±3mm; 
                                                                                     Accuracy: 0.25%; 
                                                                                     Kind: Liquid Level Transmitter; 
                                                                                     Structure: All in One; 
                                                                                     Warranty: 1 Year; 
                                                                                     Material: ABS; 
                                                                                     Process Temperature: -20℃~80℃; 
                                                                                     Measuring Range(M): 0-40m; 
                                                                                     Dead Zone: <0.25-2m; 
                                                                                     Beam Angle: <10 Deg.; 
                                                                                     Protection Rating: IP65, IP 68; 
                                                                                     Operating Frequency: 20kHz-2000kHz; 
                                                                                     Temperature Compensation: Integrated Temperature Sensor for Automatic Correc; 
                                                                                     Display: OLED English Menu; 
                                                                                     Parameter Settings: Buttons Push on Site; 
                                                                                     Analog Output: 4-20mA, 0-10V; 
                                                                                     Communication: Hart Communication, RS485 (Mod_Bus); 
                                                                                     Relays: 2 NPN/Relays (AC: 5A@250V DC: 10A@24V); 
                                                                                     Supply Voltage: DC 12-28V or AC 220V; 
                                                                                     Power Consumption: Less Than 1.5W; 
                                                                                     Process Connection: G1 1/2", M60*2, DN80 Flange,; 
                                                                                     Cable Gland: M20*1.5; 
                                                                             
                                 
                             | 
                                                    
                                
                                    
                                                                                     Principle: Ultrasonic Non-Contact Measurement; 
                                                                                     Range: 0-30m; 
                                                                                     Measurement Accuracy: ±3mm; 
                                                                                     Accuracy: 0.25%; 
                                                                                     Kind: Liquid Level Transmitter; 
                                                                                     Structure: All in One; 
                                                                                     Warranty: 1 Year; 
                                                                                     Material: ABS; 
                                                                                     Process Temperature: -20℃~80℃; 
                                                                                     Measuring Range(M): 0-40m; 
                                                                                     Dead Zone: <0.25-2m; 
                                                                                     Beam Angle: <10 Deg.; 
                                                                                     Protection Rating: IP65, IP 68; 
                                                                                     Operating Frequency: 20kHz-2000kHz; 
                                                                                     Temperature Compensation: Integrated Temperature Sensor for Automatic Correc; 
                                                                                     Display: OLED English Menu; 
                                                                                     Parameter Settings: Buttons Push on Site; 
                                                                                     Analog Output: 4-20mA, 0-10V; 
                                                                                     Communication: Hart Communication, RS485 (Mod_Bus); 
                                                                                     Relays: 2 NPN/Relays (AC: 5A@250V DC: 10A@24V); 
                                                                                     Supply Voltage: DC 12-28V or AC 220V; 
                                                                                     Power Consumption: Less Than 1.5W; 
                                                                                     Process Connection: G1 1/2", M60*2, DN80 Flange,; 
                                                                                     Cable Gland: M20*1.5; 
                                                                             
                                 
                             | 
                                                    
                                
                                    
                                                                                     Principle: Ultrasonic Non-Contact Measurement; 
                                                                                     Range: 0-30m; 
                                                                                     Measurement Accuracy: ±3mm; 
                                                                                     Accuracy: 0.25%; 
                                                                                     Kind: Liquid Level Transmitter; 
                                                                                     Structure: All in One; 
                                                                                     Warranty: 1 Year; 
                                                                                     Material: ABS; 
                                                                                     Process Temperature: -20℃~80℃; 
                                                                                     Measuring Range(M): 0-40m; 
                                                                                     Dead Zone: <0.25-2m; 
                                                                                     Beam Angle: <10 Deg.; 
                                                                                     Protection Rating: IP65, IP 68; 
                                                                                     Operating Frequency: 20kHz-2000kHz; 
                                                                                     Temperature Compensation: Integrated Temperature Sensor for Automatic Correc; 
                                                                                     Display: OLED English Menu; 
                                                                                     Parameter Settings: Buttons Push on Site; 
                                                                                     Analog Output: 4-20mA, 0-10V; 
                                                                                     Communication: Hart Communication, RS485 (Mod_Bus); 
                                                                                     Relays: 2 NPN/Relays (AC: 5A@250V DC: 10A@24V); 
                                                                                     Supply Voltage: DC 12-28V or AC 220V; 
                                                                                     Power Consumption: Less Than 1.5W; 
                                                                                     Process Connection: G1 1/2", M60*2, DN80 Flange,; 
                                                                                     Cable Gland: M20*1.5; 
                                                                             
                                 
                             | 
                                                    
                                
                                    
                                                                                     After-sales Service: 12 Months; 
                                                                                     Principle: Ultrasonic; 
                                                                                     Accuracy: 0.25%-0.5%F.S; 
                                                                                     Warranty: 1 Year; 
                                                                                     Max Level Range: 60 Meters Water Outdoor or Indoor Level Meter; 
                                                                                     Working Pressure: 2 Bar (Explore Proof Type Is 5 Bar); 
                                                                                     Power Supply: 220VAC+15% 50Hz;24VDC;120mA ;12VDC; 
                                                                                     Blind Area: 0.2-0.6m (According to Different Range and Sensor; 
                                                                                     Output: 4-20mA or RS485, or Need to Relay Output; 
                                                                                     Waterproof: IP65~IP68 by Customized; 
                                                                                     Usage: Ultrasonic Fuel Level Sensor Distance 10 Meter; 
                                                                             
                                 
                             |