Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p+N, 2p, 3p, 3p+N, 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Ka: 6ka(N); H:10ka(H);
Voltage: AC230V/400V;
AMPS: 6-80A;
Production Line: Automatic;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Intdoor Vacuum Circuit Breaker;
Orign of Place: Zhejiang ,China;
Related Voltage: up to 12kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 2500A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 20000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Outdoor Vacuum Circuit Breaker;
Related Voltage: up to 40.5kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 2500A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Weight of Sulfur Hexafluoride Gas: 7-8kkg;
Mechanical Life: 10000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Outdoor Vacuum Circuit Breaker;
Related Voltage: up to 40.5kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 2500A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Weight of Sulfur Hexafluoride Gas: 7-8kkg;
Mechanical Life: 10000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Sf6 Vacuum Circuit Breaker;
Orign of Place: Zhejiang, China;
Related Voltage: 0-12V;
Rated Frequency: 50Hz;
Rated Current: up to 1000A;
Certificate: ISO CCC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
Net Weight: 140 Kg;
|