Specification |
After-sales Service: Support Remote Online Service, Online Video Servic;
Warranty: One-Year Warranty, Lifetime Maintenance;
Max Diameter of Workpiece: 500 or Above;
Mass Scope of Workpiece: <900kg;
Type: Universal Testing Machine;
Maxcapacity: 20-100000kN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: Digital;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC110-220V;
Oil Cylinder Position: Under;
Additional Service: Support Customer Customization.;
Delivery Terms: CIF, DDP, DDU, FedEx, DHL, Fob;
Resolution: 1/150000;
Loading Precision: Under 0.5% of Full Loading Cell.;
Maximum Test Stroke: 700mm, Include Griper's Length.;
|
Max Diameter of Workpiece: 1350mm;
Mass Scope of Workpiece: 900kg;
Type: Fatigue Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Computer Display;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: AC220V;
Function: Bending;
|
Type: Universal Testing Machine;
Maxcapacity: 300kn;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: Computer Display;
Control: Computer Control;
Weight: 500-1000Kg;
Power Source: AC380V;
Displacement Resolution: 0.0005mm;
Transmission: Italy Haitec Gearbox and Tbi Precision Ball Screw;
Effective Tensile Width: 500mm;
Effective Travel: 1100mm;
Displacement Speed: 0.01-500mm/Min;
Deformation Resolution: 0.0001mm;
|
Accuracy Grade: 1;
Display: LCD;
Weight: 28kg;
Power Source: AC220V;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|
Accuracy Grade: 1;
Display: LCD;
Weight: 28kg;
Power Source: AC220V;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|