Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1P+N;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 6A, 10A, 16A, 20A,25A, 32A;
Trip curve: B,C,D;
Pole: 1P+N;
Rate voltage (Ue): 240V~;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60 Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10KA;
Electrical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection;
Rated Frequency (Hz): 50Hz;
Rated Frequency: 50/60Hz;
Number of Pole: 3;
Rated Current: 1;
Protection: Li, LSI, Lsig;
Rated Voltage: Other;
Bcd Curve: B;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Frequency (Hz): 50Hz;
Rated Frequency: 50/60Hz;
Number of Pole: 3;
Rated Current: 1;
Protection: Li, LSI, Lsig;
Rated Voltage: Other;
Bcd Curve: B;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Voltage Ui: 500V AC;
ICU: 10ka;
Frame Current: 63A;
Rated Working Voltage: Normal Voltage;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Voltage Ui: 500V AC;
ICU: 10ka;
Frame Current: 63A;
Rated Working Voltage: Normal Voltage;
|