Basic Info.
Model NO.
RST, RSNY, RSWY
Transport Package
Corrugated Carton
Product Description
Heat Shrink Termination for LV cables (Series Part No.: RST)The terminations are designed for 1-,2-,3-,4-,and 5-core cables with or without armour. The terminations are also applicable to 3+1,4+1 and 3+2 cables. The cable crutch is sealed by a breakout inner coated with adhesive. Heat shrink insulation tubes seal between the cable lug and the bottom of the core insulation. For single core cables only an insulation tube is needed. All materials are resistant to UV and weathering.
Selection TableVoltage | Cores | Cross section (sqmm) | Kit No. |
|
0.6/1(1.2)kV | 1,2,3,4,5 | 4-6 10-16 25-50 70-120 150-240 300-400 500 | 0.6/1kVRST-4(5,3,2)/(-1) 0.6/1kVRST-4(5,3,2)/0 0.6/1kVRST-4(5,3,2,1)/1 0.6/1kVRST-4(5,3,2,1)/2 0.6/1kVRST-4(5,3,2,1)/3 0.6/1kVRST-4(5,3,2,1)/4 0.6/1kVRST-4(3,2,1)/5 |
Indoor termination for screened,1-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSNY-1)The indoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. Anti-tracking insulation tube and sealing tube seal between the end of the oversheath and the cable lug. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 6kVRSNY-1/1 6kVRSNY-1/2 6kVRSNY-1/3 6kVRSNY-1/4 6kVRSNY-1/5 6kVRSNY-1/6 6kVRSNY-1/7 | 800 | - | 0 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 10kVRSNY-1/1 10kVRSNY-1/2 10kVRSNY-1/3 10kVRSNY-1/4 10kVRSNY-1/5 10kVRSNY-1/6 10kVRSNY-1/7 | 800 | - | 2 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 20kVRSNY-1/1 20kVRSNY-1/2 20kVRSNY-1/3 20kVRSNY-1/4 20kVRSNY-1/5 20kVRSNY-1/6 20kVRSNY-1/7 | 800 | 105 105 105 140 140 140 140 | 2 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 30kVRSNY-1/1 30kVRSNY-1/2 30kVRSNY-1/3 30kVRSNY-1/4 30kVRSNY-1/5 30kVRSNY-1/6 30kVRSNY-1/7 | 800 | 105 105 140 140 140 140 140 | 4 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 800-1000 1200 | 35kVRSNY-1/1 35kVRSNY-1/2 35kVRSNY-1/3 35kVRSNY-1/4 35kVRSNY-1/5 35kVRSNY-1/6 35kVRSNY-1/7 | 800 | 140 140 140 140 140 140 140 | 4 |
Outdoor termination for screened, 1-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSWY-1)The outdoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. Anti-tracking insulation tube and sealing tube seal between the end of the oversheath and the cable lug. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 6kVRSWY-1/1 6kVRSWY-1/2 6kVRSWY-1/3 6kVRSWY-1/4 6kVRSWY-1/5 6kVRSWY-1/6 6kVRSWY-1/7 | 800 | 105 105 105 105 140 140 140 | 3 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 800-1000 1200 | 10kVRSWY-1/1 10kVRSWY-1/2 10kVRSWY-1/3 10kVRSWY-1/4 10kVRSWY-1/5 10kVRSWY-1/6 10kVRSWY-1/7 | 800 | 105 105 105 105 140 140 140 | 3 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 20kVRSWY-1/1 20kVRSWY-1/2 20kVRSWY-1/3 20kVRSWY-1/4 20kVRSWY-1/5 20kVRSWY-1/6 20kVRSWY-1/7 | 800 | 105 105 105 140 140 140 140 | 4 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 800-1000 1200 | 30kVRSWY-1/1 30kVRSWY-1/2 30kVRSWY-1/3 30kVRSWY-1/4 30kVRSWY-1/5 30kVRSWY-1/6 30kVRSWY-1/7 | 800 | 105 105 140 140 140 140 140 | 6 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 800-1000 1200 | 35kVRSWY-1/1 35kVRSWY-1/2 35kVRSWY-1/3 35kVRSWY-1/4 35kVRSWY-1/5 35kVRSWY-1/6 35kVRSWY-1/7 | 800 | 140 140 140 140 140 140 140 | 6 |
Indoor termination for screened,3-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part No.: RSNY-3)The indoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. All phase cores are covered with anti-tracking insulation tube and sealing tube. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety. The crutch area is sealed and protected with an adhesive-coated breakout which is installed over the cores at the end of oversheath.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 | 6kVRSNY-3/1 6kVRSNY-3/2 6kVRSNY-3/3 6kVRSNY-3/4 6kVRSNY-3/5 | 750 | - | 0 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 | 10kVRSNY-3/1 10kVRSNY-3/2 10kVRSNY-3/3 10kVRSNY-3/4 10kVRSNY-3/5 | 750 | - | 0 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 | 20kVRSNY-3/1 20kVRSNY-3/2 20kVRSNY-3/3 20kVRSNY-3/4 20kVRSNY-3/5 | 900 | 105 105 105 140 140 | 6 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 | 30kVRSNY-3/1 30kVRSNY-3/2 30kVRSNY-3/3 30kVRSNY-3/4 30kVRSNY-3/5 | 1100 | 105 105 140 140 140 | 12 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 | 35kVRSNY-3/1 35kVRSNY-3/2 35kVRSNY-3/3 35kVRSNY-3/4 35kVRSNY-3/5 | 1100 | 140 140 140 140 140 | 12 |
Outdoor termination for screened,3-core polymeric insulated cables 6kV,10kV,20kV,30kV and 35kV (Series Part NO.: RSWY-3)The outdoor termination is designed for screened single core polymeric insulated MV cables up to 35kV. Yellow stress relief mastic is laid around the end of the screen cut. Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen end. All phase cores are covered with anti-tracking insulation tube and sealing tube. Anti-tracking rain sheds lengthen surface creepage distance to ensure safety. The crutch area is sealed and protected with an adhesive-coated breakout which is installed over the cores at the end of oversheath.
Selection TableNominal Voltage U0/U(Um) | Cross section (sqmm) | Kit No. | Diensions(mm) | No. of rain sheds |
L | D |
3.6/6(7.2)kV | 25-50 70-120 150-240 300-400 500-630 | 6kVRSWY-3/1 6kVRSWY-3/2 6kVRSWY-3/3 6kVRSWY-3/4 6kVRSWY-3/5 | 900 | 105 105 105 105 140 | 6 |
6/10(12)kV 6.35/11(12)kV 8.7/15(17.5)kV | 25-50 70-120 150-240 300-400 500-630 | 10kVRSWY-3/1 10kVRSWY-3/2 10kVRSWY-3/3 10kVRSWY-3/4 10kVRSWY-3/5 | 900 | 105 105 105 105 140 | 6 |
12/20(24)kV 12.7/22(24)kV | 35-50 70-120 150-240 300-400 500-630 | 20kVRSWY-3/1 20kVRSWY-3/2 20kVRSWY-3/3 20kVRSWY-3/4 20kVRSWY-3/5 | 900 | 105 105 105 140 140 | 12 |
18/30(36kV) 19/33(36kV) | 35-50 70-120 150-240 300-400 500-630 | 30kVRSWY-3/1 30kVRSWY-3/2 30kVRSWY-3/3 30kVRSWY-3/4 30kVRSWY-3/5 | 1100 | 105 105 140 140 140 | 18 |
20.8/36(42)kV 26/35(42)kV | 50 70-120 150-240 300-400 500-630 | 35kVRSWY-3/1 35kVRSWY-3/2 35kVRSWY-3/3 35kVRSWY-3/4 35kVRSWY-3/5 | 1100 | 140 140 140 140 140 | 18 |
Address:
2nd Floor, Phase 3, Woer Industrial Park, Lanjing North Road, Longtian St, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 9000
Company Introduction:
Woer offer a full range of products for a wide variety of applications using heat shrink, cold shrink and cold Applied technologies. Woer technology is based on specially formulated thermoplastic polymer Materials or high quality silicone rubber. The material formulas are designed, selected and mixed in our Own factory. Sophisticated process controls during extrusion, injection moulding, cross-linking and Expansion ensure high quality and reliability of our products.
Innovation is the soul of a high-tech enterprise. To achieve this, we established several material labs And two fully equipped high voltage test labs with AC voltage withstand up to 1200kV. All the labs were Authenticated by CNAS in 2011. Also, electrical, material and mechanical engineers are working in cross Functional teams focused on new technologies and product developments.