1х32 PLC splitter, steel tube, 0,9mm cable G657A1, hyytrel jacket, 1 meter length for ends, SC APC connector

Specification For plc Splitter

 

Description

PLC(PlanarLightwaveCircuit)splittersareusedtodistributeorcombineopticalsignals.Itisbasedonplanarlightwavecircuittechnologyandprovidesalowcostlightdistributionsolutionwithsmallformfactorandhighreliability.

 

Fiberopticalsplitterisusedtosplitthefiberopticlightintoseveralpartsatacertainratio.ThefiberopticsplitterisanimportantpassivecomponentusedinPONFTTXnetworks.TherearemainlytwokindsofpassiveFTTHopticalsplitters:oneisthetraditionalfusedtypesplitterasknownasFBTcouplerorFBTWDMopticalsplitter,whichfeaturescompetitiveprice;theotheristhePLCsplitterbasedonthePLC(PlanarLightwaveCircuit)technology,which has a compact size and suits for density applications.

 

4. Rack type PLC splitter

NO.

Model

Splitting ratio

Dimension   (L*W*H)(mm)

1

1*2, 2*2 Rack   type

1*2, 2*2

410*200*44.5

2

1*4, 2*4 Rack   type

1*4, 2*4

410*200*44.5

3

1*8, 2*8 Rack   type

1*8, 2*8

410*200*44.5

4

1*16, 2*16 Rack   type

1*16, 2*16

410*200*44.5

5

1*32, 2*32 Rack   type

1*32, 2*32

410*200*44.5

6

1*64, 2*64 Rack   type

1*64, 2*64

410*200*85

 

1*N Tray type PLC splitter

 

  

 

 
1*2-1*32 Ract type PLC splitter1/2*64 Ract type PLC splitter

 

 

1:N Optical performance with connectors

Items

1*2

1*4

1*8

1*16

1*32

1

Working wavelength (nm)

1260-1650

2

Insetion Loss (dB)

Max

4

7.4

10.5

13.8

17.1

3

Polarization Dependent Loss (dB)

Max

0.2

0.2

0.3

0.3

0.3

4

Return Loss (dB)

Max

55

55

55

55

55

5

Uniformity (dB)

Max

0.4

0.7

1

1

1.5

6

Directivity (dB)

Max

55

55

55

55

55

 

PLC Test Specification

 Insert/Pull Test

Loss should be within the following limits in reference to the initial value:

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 d

-  Return loss should be ≥50 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  Pull/Insert:500 times

-  Record a data every 10 times

-  Data is recorded 50 times in total

-  Clean pins and adapter's elastic sleeve before recording very time

-  Not mechanical damage, such as deformation, loss, corrosion, relaxation and other phenomena

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Tensile Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥55 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  Load: 4 N

-  Tensile variation in process of testing: 1N/s

-  Duration:60s

-  Tensile Point:0.22‐0.28m distance from fiber cable ends

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Torsion Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  Applied force:7.4N

-  The distance between the Torsion point and shell underside is 0.2cm

-  Max Torsion Angle: ±180°

-  Number of torsions: 100 times

-  Torsion Speed:10 Times/min.

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

High and Low Temperature Cycling Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  High Temperature=+75ºC,Temperature rate of change:1 ºC / min

-  Low Temperature=‐25ºC,Temperature change rate 1 ºC / min

-  High and low temperature points to stay four hours separately

-  Duration: 96h

-  Cycles: 12 times

-  2 hours returned to 25ºC

-  Keep 2 hours at 25ºC,then test

-  Insertion value should be tested at least one time per 10 mins. in process of testing.

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Low Temperature Test

Loss should be within the following limits in reference to the initial value

-  variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

 

The test shall be conducted under the following conditions:

-  Temperature=‐25ºC

-  Duration:96H

-  2 hours returned to 25ºC from ‐25ºC

-  Test after Keeping 2 hours at 25ºC

-  Insertion value should be tested at least one time per 60 mins. in process of testing.

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Dry Heat Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  Temperature=+75ºC

-  Duration: 96h

-  2 hours returned to 25ºC

-  Test after Keeping 2 hours at 25ºC

-  Insertion value should be tested at least one time per 60 mins. in process of testing.

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Salt Spray Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50 dB in process of Testing

 

The test shall be conducted under the following conditions:

-  Salt Spray concentration: 5%

-  Condition:35ºC,48H

-  Test its optical performance at room temperature, and record data

-  Place in salt spray chamber from the test system, heated to 35  ,then  ºC keep 48H

-  Lower temperature to room temperature, remove the samples to place 2H, test the optical performance after

-  No mechanical damage, such as deformation, loss, corrosion, relaxation and other phenomena

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Vibration Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50dB in process of testing

 

The test shall be conducted under the following conditions:

-  Frequency:10‐55 Hz

-  Amplitude:0.75mm (1.52mm Max)

-  Cycles: 15 times

-  Time: 90 min divided in three perpendicular directions

-  Every 5 seconds to test the attenuation of at least one port

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Humidity Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50dB in process of testing

 

The test shall be conducted under the following conditions:

-  Temperature=+40ºC

-  Humidity =93%

-  Duration: 96 h

-  25ºC 2 hours returned to 25ºC

-  Test after Keeping 2 hours at 25ºC

-  Insertion value should be tested at least one time per 60 mins. in process of testing

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Water Immersion Test

Loss should be within the following limits in reference to the initial value

-  Variation value of Insertion Loss should be ≤0.50 dB in process of testing

-  The difference between Initial Value and final test value should be ≤0.30 dB

-  Return loss should be ≥50dB in process of testing

 

The test shall be conducted under the following conditions:

-  Elevation of water:15mm

-  Temperature:43ºC

-  Soaking time:168 h

-  Insertion value should be tested at least one time per 10 mins. in process of testing

-  Test Wavelength 1310‐1550nm

-  Required testing interface QTY=log22(Output interface):log2(8)=3

 

Flame Retardant Requirments

Test standard

-  HB: UL94 standard anti‐flame retardant is the lowest grade

-  Ask for 3 to 13 mm thick samples, the burning rate of less than 40 mm per minute

-  Samples less than 3 mm thick, the burning rate per minute less than 70 mm or 100 mm sign is extinguished

-  V‐2: After samples twice fire test for 10 seconds the flame extinguished within 60 seconds and Blazers fall

-  V‐1: After samples twice fire test for 10 seconds the flame extinguished within 60 seconds and No Blazers fall

-  V‐0: After samples twice fire test for 10 seconds the flame extinguished within 30 seconds. No Blazers fall

-  Optical splitter, Optical cable and ABS housings should com

Address: No. 62, Sujie Village, Houzhai Street, Jinhua, Zhejiang, China
Business Type: Manufacturer/Factory
Business Range: Computer Products, Consumer Electronics, Electrical & Electronics, Industrial Equipment & Components
Main Products: Fiber & Cable
Company Introduction: Our mission is:

Perceiving customer needs at utmost level by providing them flexibility in sourcing, competitive prices, on-time deliveries and customized solutions for unique needs

Ensuring attentive, effective and proactive customer service and personalized attention to customers

Continually building our skills and knowledge to meet the growing and diverse needs of customers

Sustaining our reputation as a reliable, customer-oriented, dynamic player in the market

Achieving profitable growth, operational and organizational excellence without compromising from our values and business ethics

Our values are;

Loyalty,

Honesty,

Integrity,

Reliability,

Transparency,

Mutual Respect

Our vision is;

Being a globally recognized company established world-wide with an excellence in organizational structure

Re-defining the standards of ′customer service′ by exceeding customer expectations

Being admired for our business values and ethics

Keeping our name synonymous with reliability, customer satisfaction and innovation.

Being the "preferred choice" both for customers, suppliers and employees

Bringing inspiration and being a model for companies who are willing to reach their dreams
Once receive your question, the supplier will answer you as soon as possible.

Send your message to this supplier

Post a Sourcing Request Now

Last Login Date: May 10, 2023

Business Type: Manufacturer/Factory

Main Products: Fiber & Cable

Related Categories