Specification |
Classification: Imaging Diagnostic Equipment;
Type: Vein Finding Device;
Intended Application: Vein Finding Device;
Electric Current: 1.5A;
Light Source: Near Infrared Light;
Power Consumption: 80va;
Best Detection Distance: 15-25cm;
Project Alignment Accuracy: 0.3mm;
Machine Size: 20cm*6.2cm*5.5cm;
|
Classification: Pathology Equipment;
Type: Automatic and Semi-Automatic Microtome;
Group: All;
Mode: Semi-Automatic Without Intelligent Sensing;
Display: LCD Display;
Sectioning Thickness Range: 0~60μm;
Trimming Thickness Range: 0 ~60, 0~100, 1~900μm;
Specimen Horizontalstroke: 28mm;
Specimen Vertical Stroke: 52 mm;
Specimen Orientation: Xy – 8°, Rotation 360°;
Xy – 8°, Rotation 360°: 0.25μm;
Max. Specimen Size: 50*70mm;
Feed Speed: 450μm/S;
Precision: ±5%;
Consumption: 100W;
|
Classification: Pathology Equipment;
Type: Automatic and Semi-Automatic Microtome;
Group: All;
Mode: Automatic or Manual Mode Without Intelligent Sensi;
Retraction Range: 0~50μm;
Display: LED Display;
Sectioning Thickness Range: 0.25~100μm;
Trimming Thickness Range: 1~600μm;
Specimen Horizontalstroke: 28mm;
Specimen Vertical Stroke: 70mm;
Specimen Orientation: Xy – 8°, Rotation ±90°;
Mini. Sectioning Thickness: 0.25μm;
Max. Specimen Size: 70*70mm;
Feed Speed: 1500μm/S,3500μm/S;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Types: Random, Discrete, Fully Automatic;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate, Turbidimetry;
Sample Volume: 2μl~70μl (0.1μl Stepping);
Light Source: Halogen Lamp (Grating Optional);
Stray Light: <0.1% or ABS >3.0;
Data Processing: Reaction Curve and Data Display Function;
Power Supply: AC110/220V±10%, 60/50Hz;
Model: Bk-200mini( New Bk-200);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Mixer Probe: Independent Stirring;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Model: Biobase-Silver;
Reading Cuvette: Both Through Cell and Direct Reading Cuvette;
Incubating Positions: 20 Incubation Positions;
Photometric System: Light Source: 6V, 10W Halogen Lamp;
Measuring System: Measuring Range: 0~2.500 Od;
Incubator Temperature Control: Rt+25ºC, 30ºC, 37ºC;
Display/Keyboard: Touch Screen;
Printer: Built-in Thermal Printer;
Interface: RS-232, USB;
Power Supply: AC110/220V±10% 60/50Hz;
Software: Windows 7/8/10, Lis System Available;
External Size (W*D*H): 340*380*180mm;
Package Size (W*D*H): 575*490*350mm;
Gross Weight: 19kg;
Humidity: 30-80%;
|