Specification |
Type: Smoke Sensor Probe;
Anti-theft Alarm System Approach: Active;
Anti-Theft Alarm System Type: Smoke Alarms;
Anti-Theft Alarm System-Wide: Space Security Alarm Detector;
Types of Smoke Detectors: Photoelectric Smoke Style;
|
Type: Smoke Detectors;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤120μa;
Alarm Current: 10mA≤I≤30mA;
Indicator: Red LED;
Power-on Time: ≤10s;
Atmospheric Pressure: 80~110kpa;
The Highest Wind Speed: 7.6m/S (1500FPM);
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤120μa;
Alarm Current: 10mA≤I≤30mA;
Indicator: Red LED;
Power-on Time: ≤10s;
Atmospheric Pressure: 80~110kpa;
The Highest Wind Speed: 7.6m/S (1500FPM);
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Smoke Detectors;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Smoke Detector;
Operating Voltage: 24VDC;
Standby Current: ≤120μa;
Alarm Current: 10mA≤I≤30mA;
Indicator: Red LED;
Power-on Time: ≤10s;
Atmospheric Pressure: 80~110kpa;
The Highest Wind Speed: 7.6m/S (1500FPM);
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II Bt6 CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|
Type: Temperature Sensor Probe;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Fixed Temperature;
Infrared Sensor Installation: Ceiling;
Product Name: Explosion Proof Heat Detector;
Operating Voltage: 24VDC;
Standby Current: ≤60μa;
Alarm Current: ≤10mA;
Indicator: Red LED;
Power-on Time: ≤30s;
Atmospheric Pressure: 80~110kpa;
Alarm Temperature: 57ºC;
Output Type: Relay Contact;
Explosion Proof Mark: Exd (Ib) II CT6;
Dimention: About 100mm X 150mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Heat Detection;
Application: Factory, Warehouse,Pharmaceutical Plant, etc.;
|