Specification |
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire;
Alarm Volume (within 1m): ≥100dB;
Networking Mode: TCP/IP;
Wiring Mode: Bus System;
Capacity: Max 8 Loop;
Power Supply: 24V DC;
Battery: 12V2ah*2;
Fire Relay Output: Nc and No;
Fault Relay Output: Nc and No;
Sounder Output: 2 Circuits;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|