Specification |
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Reading Cuvette: Both Through Cell and Direct Reading Cuvette;
Incubating Positions: 20 Incubation Positions;
Measuring Range: 0~2.500 Od;
Wavelength Accuracy: ±2nm;
Incubator Temperature: R.T. 25ºC, 30ºC, 37;
Control: Precision: ±0.1ºC;
Display: Touch Screen;
Printer: Built-in Thermal Printer;
Interface: RS-232, USB;
Power Supply: AC110/220V±10%, 60/50Hz;
External Size(W*D*H): 400*380*200mm;
Packing Size(W*D*H): 500*530*350mm;
Gross Weight: 12kg;
|
Classification: Imaging Diagnostic Equipment;
Type: Disposable Sample Tube;
Group: Female;
Product Name: Urine Analyzer Bh-Ny01;
Principle: Computer Vision Detection Technology;
Throughput: 700tests / Hour;
Screen: 7-Inch Touch Screen;
Printer: Built-in Thermal Printer;
Working Condition: Temperature 5-40ºC Humidity <85%;
Range of Application: 11, 14 Test Strip;
Power Supply: AC100-240V,50/60Hz, 40va;
Net Weight: 4kg;
Gross Weight: 8kg;
External Size(W*D*H): 346*320*206mm;
Package Size(W*D*H): 425*385*305mm;
|
Classification: Imaging Diagnostic Equipment;
Type: Nucleic Acid Extraction System;
Group: All;
Model: Bk-Autohs96;
Throughput: 48 Sample/Batch (MB); 96 Sample/Batch(Ot);
Extraction Time: MB: 48 Samples/120min; Ot: 96 Samples/40min;
Sample: Serum, Plasma, Throat Swab, Anal Swab, Stool, Repr;
Consumable: All Size Blood Tubes, 1.5ml/2.0ml Centrifuge Tubes;
Supported Reagent: PRO HBV, HCV, Hpv, Stds, Eb, Hcmv, Tb, Hfmd and Et;
Extraction Volume: 1-3ml;
Pipetting Volume: 10-1800μl;
Pipetting Tip: 2 Channel Tip;
Operating Temperature: 15-22ºC;
Ambient Humidity: 30-80%;
Illumination: White Cold Light Source;
Software: Build-in Operation Software with Error Self-Check;
|
Classification: Biochemical Apparatus;
Type: Biochemistry Analyzer;
Group: All;
Throughput: 200tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Certificates: CE, FDA, ISO9001, ISO14001, ISO13485;
Sample Positions: 49 Sample Positions;
Reagent Positions: 56 Reagent Positions;
Sample Volume: 2~70μl;
Reagent Volume: 20~350μl;
Temperature Control: 37±0.1ºC, Real-Time Monitor;
Package Size (W*D*H): 1118*728*1151mm;
Gross Weight: 130kg;
Cuvettes: 120 Reusable Cuvettes,Optical Length 6mm;
Mixerprobe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
Light Source: 12V/30W Halogen Lamp;
|
Classification: Imaging Diagnostic Equipment;
Type: Digital Thermometer;
Group: All;
Detector Pixel: 640*512;
|