Specification |
Type: Fire Alarm Host;
Function: Non-Networked;
Usage: Fire;
Product Name: Addressable Fire Alarm System Control Panel;
Main Power Supply: AC220V± 15%, 50Hz.;
Dimensions: 450mmx370mmx120mm;
Capacity: 1A/24V;
Battery Power Output: 1 Group 24V Power Output Output;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: TCP/IP;
Receive Frequency: 229.95MHz;
Wiring Mode: Bus System;
Approvals: Lpcb / CE-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: TCP/IP;
Receive Frequency: 229.95MHz;
Wiring Mode: Bus System;
Approvals: Lpcb / CE-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Usage: Fire, Smoke;
Mains Supply: 110V/230V* AC (-15%, +10%),50Hz*/60Hz;
Operating Voltage: 20 ~ 28VDC;
Power Rating: Imin=0.15A; Imax.a=1.15A; Imax.B=1.65A;
Max. Battery Supply Current: 3A (When The Mains Is Disconnected);
Battery Capacity, Type: Np7-12 for 7ah VRLA(Yuasa);
Np7-12 for 7ah VRLA(Yuasa): 1Ω;
Battery Fuse: F6al250V;
Recommended Mains Cable: Standard/Black Mains Cable, Cable Size 0.75mm2;
|
Type: Fire Alarm Host;
Usage: Fire, Smoke;
Mains Supply: 110V/230V* AC (-15%, +10%),50Hz*/60Hz;
Operating Voltage: 20 ~ 28VDC;
Power Rating: Imin=0.15A; Imax.a=1.15A; Imax.B=1.65A;
Max. Battery Supply Current: 3A (When The Mains Is Disconnected);
Battery Capacity, Type: Np7-12 for 7ah VRLA(Yuasa);
Np7-12 for 7ah VRLA(Yuasa): 1Ω;
Battery Fuse: F6al250V;
Recommended Mains Cable: Standard/Black Mains Cable, Cable Size 0.75mm2;
|