Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection;
Rated Frequency (Hz): 50Hz;
Rated Frequency: 50/60Hz;
Number of Pole: 3;
Rated Current: 1;
Protection: Li, LSI, Lsig;
Rated Voltage: Other;
Bcd Curve: B;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Product Name: MCCB(Molded Case Circuit Breaker);
Poles: 2p;
Frame Current(Inm): 100af;
Rated Current: 60A;
Rated Voltage(Ue): AC 660V;
Rated Frequency: 50/60 Hz;
Break Capacity: 25ka at 220/240VAC;
Rated Insulation Voltage Ui(V): 690V;
Rated Impulse Withstand Voltage Uimp(Kv): 6kv;
Color: Grey/ White;
Standard: IEC60947-2/GB14048.2;
Material: High Quality Bakelite, Silver, Copper;
Mechanical Life: 12000 Times;
Certificate: CE, Ks, CCC, ISO9001;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: High Voltage Vacuum Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Name: Indoor High Voltage Vacuum Circuit Breaker;
Frequency: 50Hz;
Rated Voltage: 12kv;
Feature: High Reliability/Miniaturization;
|