Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: DC Immune Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Cascade Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.1;
Turns Ratio: 2500:1;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Winding Material: Copper;
Frequency: 50/60 Hz;
MOQ: 1 Piece;
Ambient Temperature: -20-40;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Winding Material: Copper;
Frequency: 50/60 Hz;
MOQ: 1 Piece;
Ambient Temperature: -20-40;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Winding Material: Copper;
Frequency: 50/60 Hz;
MOQ: 1 Piece;
Ambient Temperature: -20-40;
|
Application: Electronic, Instrument, Power System;
Type: Combined Instrument Transformers Measuring Box;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Insulating Oil;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Primary Current: 5-1000A;
Rated Voltage Ratio: 10000/100V,6000/100V;
Rated Voltage: 10kv;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Accuracy Level: 0.2s,0.2,0.5s;
Rated Capacity: Voltage Part: 0.2 Class, 20va;
Rated Capacity:Current Part: 0.2s, 0.2 Class, 10va;
Rated Short-Time Thermal Current Multipl: 100I1n/1s;
Rated Short-Time Dynamic Stability Multi: 250I1n;
Rated Secondary Output: 10va;
Rated Short Time Thermal Current: 1.5-80ka;
Rated Dynamic Stable Current: 2.5-100ka;
|