What is MCCB Dam3-630 3p 400-630A CB Approved Molded Case Circuit Breaker

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1000 Pieces US$55.00-66.00 / Piece

Sepcifications

  • Breaking Capacity Low Voltage Circuit Breakers
  • Operation Manual Type
  • Speed Normal Type Circuit Breaker
  • Arc-extinguishing Medium Arc Chamber
  • Installation Fixed
  • Structure MCCB
  • Poles Number 3
  • Type Circuit Breaker
  • Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
  • Certification ISO9001-2000, CE, CB, CCC, RoHS
  • Transport Package Carton
  • Specification 400, 500, 630A
  • Trademark CDADA, OEM, ODM
  • Origin Shanghai, China
  • Base BMC Unflaming Material
  • Terminal with Terminal Box

Product Description

Overview The rated current of DAM3-630 molded case circuit breaker can reach up to 630A. These electrical devices are suitable for the protection of power distribution circuits with an alternating current of 50-60Hz and a rated operating current up to 1600A. They can also be used in electric ...

Learn More

Compact Size MCCB Comparison
Transaction Info
Price US $ 55.00-66.00/ Piece US $ 43.00-44.00/ Piece US $ 86.00-88.00/ Piece US $ 260.00-266.00/ Piece US $ 34.00-35.00/ Piece
Min Order 1000 Pieces 10 Pieces 10 Pieces 10 Pieces 10 Pieces
Trade Terms - - - - -
Payment Terms L/C, T/T L/C, T/T, Paypal L/C, T/T, Paypal L/C, T/T, Paypal L/C, T/T, Paypal
Quality Control
Product Certification ISO9001-2000, CE, CB, CCC, RoHS ISO9001-2000, CE, CCC ISO9001-2000, CE, CCC ISO9001-2000, CE, CCC ISO9001-2000, CE, CCC
Management System Certification ISO 9001 ISO 9001 ISO 9001 ISO 9001 ISO 9001
Trade Capacity
Export Markets South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe Europe Europe Europe Europe
Annual Export Revenue - - - - -
Business Model OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand
Average Lead Time Off-season: 1 Month(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Product Attributes
Specification
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Arc Chamber;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Base: BMC Unflaming Material;
Terminal: with Terminal Box;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 225/250/315/350/400A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 630/700/800A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
ICU: 65ka;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 630/700/800/1000/1250A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
ICU: 80ka;
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 100/125/160/180/200/225A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
ICU: 35ka;
Supplier Name

Shanghai DaDa Electric Co., Ltd.

China Supplier - Diamond Member Audited Supplier

SaiLingsi (wenzhou) Electronics Co., LTD

China Supplier - Gold Member Audited Supplier

SaiLingsi (wenzhou) Electronics Co., LTD

China Supplier - Gold Member Audited Supplier

SaiLingsi (wenzhou) Electronics Co., LTD

China Supplier - Gold Member Audited Supplier

SaiLingsi (wenzhou) Electronics Co., LTD

China Supplier - Gold Member Audited Supplier