Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Infusion Pump;
Group: All People;
Product Name: Infusion Pump;
Drug Library: up to 1030 Drugs Are Provided.;
Certificate: CE, ISO13485;
Cumulative Infusion Volume: 0-9999.9ml;
Kvo Rate: 0.1 ~ 5.0ml/H;
Infusion Accuracy: 2%;
Power Supply: AC100-220V, 50/60Hz;
Features: Easy to Carry, Easy to Operate;
Infusion Set: Any Brand of Infusion Set;
Infusion Mode: Rate, Time, Dose, Drug Library and Sequential Mode;
Air Bubble Detection: Ultrasound Sensor Detection of Air Bubble;
|
Classification: Biochemical Apparatus;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Product Name: Elisa Microplate Reader;
Microplate Types: 48-Well, 96-Well;
Washing: Automatic Washing, 5 Ways;
Washing The Row: 1 Row Per Time;
Number of Microplate: 1- 12 Rows;
Average Residue: ≤2UL Per Well;
Dispense Precision: CV≤3%;
Shaking: 5 Ways;
Memory: 100 Programs;
Wash Cycles: 1~20;
Soak Time: Programmable in Seconds, up to 20 Minutes;
Anti-Overflow: Excess Fluid Is Automatically Discharged.;
Power Supply: AC110/220V±10%,60/50Hz;
Package Size(W*D*H): 716*696*300mm;
Gross Weight: 18 Kg;
|
Classification: Imaging Diagnostic Equipment;
Type: Ultrasound Scanner;
Group: All;
|
Classification: Biochemical Apparatus;
Type: Fluorescence Quantitative PCR Detection System;
Group: All People;
Product Name: Fluorescence Quantitative PCR Detection System;
Sample Capacity: 96X0.1ml PCR Plate, 12X8-Strip Tubes, 96*0.1ml Sin;
Reaction System: 10~50μl;
Dynamics Range: 1-1010 Copies;
Channel: 4;
Emission Light: LED;
Detector: Pd;
Excitation Wavelength: 455~645nm;
Detection Wavelength: 510~710nm;
Module Temp. Range: 4-105 Degree;
Ramp Rate: 7.0 Degree;
Temp. Control Mode: Block Mode;
Hot-Lid Temp. Range: 30-110 Degree;
Scanning Mode: Full Plate Scanning;
Programming: Max 100 Segments for Each Program, Max 99 Cycles;
|
Classification: Biochemical Apparatus;
Type: Biochemistry Analyzer;
Group: All;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Mixer Probe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
|