Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: RCCB;
in: 63A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-1, GB14048-2;
Rated curret (In): 80A,100A,125A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 500V;
Rated Current: 80A,100A,125A;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Electrical life: 20000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
Insultation Voltage (Ui): 500V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Frequency (Hz): 50Hz;
Rated Frequency: 50/60Hz;
Number of Pole: 3;
Rated Current: 1;
Protection: Li, LSI, Lsig;
Rated Voltage: Other;
Bcd Curve: B;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection;
Rated Frequency (Hz): 50Hz;
Rated Frequency: 50/60Hz;
Number of Pole: 3;
Rated Current: 1;
Protection: Li, LSI, Lsig;
Rated Voltage: Other;
Bcd Curve: B;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60898-1, GB10963-1;
Rated curret (In): 80A,100A,125A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A,25A, 32A, 40A, 5;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
Insultation Voltage (Ui): 500V;
|