Specification |
Classification: Imaging Diagnostic Equipment;
Type: X Ray Equipment;
Group: Middle-aged and Old;
Logo: Accept Customized Logo;
Size: Contact Us for More;
Suitable for: Medical X Ray Machine;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Name: Chemistry Analyzer;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1ºC, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Mixer Probe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
|
Classification: Imaging Diagnostic Equipment;
Type: Patient Monitor;
Group: All People;
Product Name: Pulse Oximeter;
Display: LED;
Patient Range: Adult,Child and Neonate;
Assay Items: SpO2 Measurement Range;
SpO2 Resolution: 1%;
SpO2 Accuracy: 2%(70%~99%);Unspecified(0%~100%);
Temperature Channel: 2;
Temperature Input: Body Surface Thermal-Sensitive Resistor Temperatur;
Temperature Range: 0 Degree ~50 Degree;
Temperature Resolution: 0.1 Degree;
Power Supply: Common 1.5V AA Alkaline Batteries(Only for Bk-Po1);
Standard Accessories: Oximeter Main Unit/ Adult Finger SpO2 Sensor;
Package Size(W*D*H): 220*150*70mm;
Gross Weight: 1.0kg;
Temperature Accuracy: 0.2 Degree;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Biochemistry Analyzer;
Group: All;
Model: Bk-200 (New Bk-280);
Throughput: 200tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic), Turbidimetry;
Sample Positions: 49 Sample Positions;
Reagent Positions: 56 Reagent Positions;
Probewashing: Automaticwashing Interior and Exterior;
Reagentcooling: Refrigerated Tray with Independent Switch;
Cuvettes: 120 Reusable Cuvettes,Optical Length 6mm;
Mixerprobe: Independent Stirring;
Washing: Automatic Cuvettes Washing;
Stat Function: Yes;
Light Source: 12V/30W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
Absorbance: 0~3.0ABS;
|
Classification: Biological Diagnostics;
Type: Fat Analyzer;
Group: Milk/Food/Grain;
Temp. Range: Rt +5ºC~300ºC;
Measuring Range: 0.1~100%;
Temperature Accuracy: ±1ºC;
Repeatability: Relative Error 1%;
Sample Weight: 0.5~15g;
Capacity: 6PCS/Batch;
Solvent Cup Volume: 150ml;
Solvent Recovery: ≥85%;
Consumption: 2.0kw;
Power Supply: AC 220V±10%, 50Hz;
External Size(W*D*H): 650*348*875mm;
Package Size(W*D*H): Main Body:835*540*930mm / Accessories:450*310*245m;
Gross Weight: Main Body:92kg /Accessories:4.5kg;
|