Specification |
Application: Power, Electronic, Instrument, Lighting;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EI;
Brand: Hensiron;
Advantage: Small No-Load Loss, Low Temperature Rise;
Installation Methods: Pin Type, Bracket Type, DIP Type, etc.;
Material: High-Quality Silicon Steel Sheet;
Wide Application Use: Yes;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 1600kVA;
Rated H. V: 11 Kv;
Rated L. V: 0.4kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 1000kVA;
Rated H. V: 11 Kv;
Rated L. V: 0.4kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Rated Capacity: 400~3000 kVA;
Voltage (Hv) (Kv): 10 KV 11KV 12.47KV 13.2KV13.8KV 20KV 33KV 34.5KV;
Voltage (LV) (Kv): 0.4kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 63kVA;
Rated H. V: 6kv;
Rated L. V: 0.4kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|