Specification |
Display Type: Digital Only;
Customized: Customized;
Impedance Measurement Range: 0~200 Ohm;;
Resolution: 0.001 Ohm;
Maximum Output Voltage: AC 400V (45Hz,55Hz, Double Frequency, Sine Wave);
Maximum Output Current: AC 3A (45Hz,55Hz, Double Frequency, Sine Wave);
Current Output Gear: 3/2.5/2/1.5/1A;
Anti-Jamming Capability: Anti- Frequency 50Hz Voltage 10V;
Measured Wire Required Value-1: Current Wire Copper  Core More Than 1.5 mm2;
Measured Wire Required Value-2: Voltage Wire Copper  Core More Than 1.0 mm2;
Dimension: 295*340*310mm3;
Weight: 28kg;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Display Type: Analogue and Digital;
Customized: Customized;
Product Name: Partial Discharge Tester;
Test Channels: 4;
Test Range: 0.1 PC ~ 100,000 PC;
Test Method: Ultrasonic, Hfct, UHF, Tev;
Typical Application: Power Transformer, Gis, Switchgear, Cable;
Spectrogram Mode: Prps, Prpd, Wave;
Synchronization Mode: Internal, External, Optical;
Sampling Accuracy: 12 Bit;
Weight: 15 Kg;
Dimensions: 470 X 285 X 370 mm;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Display Type: Analogue and Digital;
Customized: Customized;
Product Name: Power Quality Analysis Pad;
Channels: 4 Voltage Channels/4 Current Channels;
Voltage Range: 10 to 900 V;
Current Range(Built-in): 0 to 25 a;
Current Range*: 5 a/50 a/ 100 a/ 500 a/ 1500 a/ 2000 a...;
Dimensions: 280 X 210 X 58 mm;
Weight: 2 Kg;
Screen: 1280 X 800 Touch LCD Screen;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Display Type: Analogue and Digital;
Customized: Customized;
Product Name: Automated Six-Winding Transformer Ohmmeter;
Measuring Range: 500 μΩ ~ 200 Ω;
Current Output: 50 Ma to 40 a;
Resolution: 0.0001 μΩ;
Accuracy: ±0.2%;
Operating Temperature: -10ºC~50ºC;
Dimensions: 370 mm * 260 mm * 190 mm;
Back-Emf Protection Function: Automatic Saturation Magnetic Circuit Method;
|
After-sales Service: 7*24 Online Service/Change New;
Warranty: 1 Year;
Display Type: Digital Only;
Customized: Customized;
Phase Accurrent Output (Effective Value): 0~40A/Phase, Accuracy 0.5%;
3 Phase Parallel Current Output (Effecti: 0~120A/3 Phase Parallel Output in Same Phase;
Phase Current Working Value for Allowed: 10A;
Maximum Output Power of Each Phase: 420va;
Maximum Output Power of 3 Parallel Curre: 900va;
Maximum Permitted Work Time of 3 Paralle: 10s;
DC Frequency Range: 0~1000Hz; Accuracy: 0.001Hz;
Harmonic Time: 2~20;
Phase: 0--360°; Accuracy: 0.1°;
DC Current Output: 0~±30A / Phase, Accuracy:0.5%;
Phase AC Vol Output (Effective Value): 0~125V/Phase, Accuracy: 0.5%;
Line AC Voltage Output (Effective Value): 0~250V;
Phase Voltage / Line Voltage Output Powe: 75va / 100va;
AC Frequency Range: 0~1000Hz Accuracy: 0.001Hz;
Switch Input Terminals: 8 Pairs;
|