Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Magnetic Blow-out;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Surface Protection: Zinc Plated;
Grid Material: Iron;
Assembly: Automatic Arc Chute Assembly Machine;
Craft: Stamping Mould;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Number of Poles: 3/4;
Rated Current in: 12.5,16,20,25,32,40,50,63,400,630,800,1250,1600;
Rated Insulation Voltage Ui: 500V/400V/690V;
Rated Operating Voltage Ue: 230V/400V;
Dielectric Property: 2500V;
Standard: IEC60947-2;
Rated Impluse Withstand Voltage Uimp (Kv: 8;
Rated Insulation Voltage Ui (V): 800;
Mechanical Endurance: 8500;
Electrical Endurance: 1500;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Number of Poles: 3/4;
Rated Current in: 12.5,16,20,25,32,40,50,63,400,630,800,1250,1600;
Rated Insulation Voltage Ui: 500V/400V/690V;
Rated Operating Voltage Ue: 230V/400V;
Dielectric Property: 2500V;
Standard: IEC60947-2;
Rated Insulation Voltage Ui (V): 800;
Rated Impluse Withstand Voltage Uimp(Kv): 8;
Mechanical Endurance: 4000;
Electrical Endurance: 1000;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Number of Poles: 3/4;
Rated Current in: 12.5,16,20,25,32,40,50,63,400,630,800,1250,1600;
Rated Insulation Voltage Ui: 500V/400V/690V;
Rated Operating Voltage Ue: 230V/400V;
Dielectric Property: 2500V;
Standard: IEC60947-2;
Rated Insulation Voltage Ui (V): 800;
Rated Impluse Withstand Voltage Uimp(Kv): 8;
Mechanical Endurance: 4000;
Electrical Endurance: 1000;
Fixed Magnetic Trip: Has This Option;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Number of Poles: 3/4;
Rated Current in: 12.5,16,20,25,32,40,50,63,400,630,800,1250,1600;
Rated Insulation Voltage Ui: 500V/400V/690V;
Rated Operating Voltage Ue: 230V/400V;
Dielectric Property: 2500V;
Standard: IEC60947-2;
Rated Insulation Voltage Ui (V): 800;
Rated Impluse Withstand Voltage Uimp Kv: 8;
Mechanical Endurance: 8500;
Electrical Endurance: 1500;
|