Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Magnetic Blow-out;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Rated Current (a): 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Rated Voltage: 1pole 230/400V AC 50/60Hz,2,3,4pole 400V AC 50/60h;
Ambient Temperature: -5octo +40ocpursuant to En / IEC60898;
Number of Poles: 1p,1p+N,2p,3p,3p+N and 4p;
Standard: En/IEC60898-1;
Protection: Against Overload and Short Circuit;
Rated Insulation Voltage Ui: 500V;
Rated Impulse Withstand Voltage Uimp: 4kv;
Energy Limiting: Class 3.0;
Type of Trip: Thermal /Magnetic Release;
Type of Terminal: Lug Type and Pin Type;
Protection Degree: IP20;
Width: 17.8mm Per Pole;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Rated Current (a): 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Rated Voltage: 1pole 230/400V AC 50/60Hz,2,3,4pole 400V AC 50/60h;
Ambient Temperature: -5octo +40ocpursuant;
Number of Poles: 1p,1p+N,2p,3p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Protection Degree: IP20;
Type of Trip: Thermal /Magnetic Release;
Type of Terminal: Lug Type and Pin Type;
Width: 17.8mm Per Pole;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: En/IEC 60898-1;
Rated Current (a): 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Rated Voltage: 1pole 230/400V AC 50/60Hz,2,3,4pole 400V AC 50/60h;
Ambient Temperature: -5octo +40ocpursuant to En / IEC60898;
Number of Poles: 1p,1p+N,2p,3p,3p+N and 4p;
Rated Insulation Voltage Ui: 500V;
Rated Impulse Withstand Voltgage Uimp: 4kv;
Energy Limiting: Class 3.0;
Type of Trip: Thermal /Magnetic Release;
Type of Terminal: Lug Type and Pin Type;
Width: 17.8mm Per Pole;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: En/IEC60898-1;
Rated Current (a): 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Rated Voltage: 1pole 230/400V AC 50/60Hz,2,3,4pole 400V AC 50/60h;
Ambient Temperature: -5octo +40ocpursuant to En / IEC60898;
Number of Poles: 1p,1p+N,2p,3p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Protection Degree: IP20;
Rated Insulation Voltage Ui: 500V;
Rated Impulse Withstand Voltage Uimp: 4kv;
Energy Limiting: Class 3.0;
Type of Trip: Thermal /Magnetic Release;
Type of Terminal: Lug Type and Pin Type;
Width: 17.8mm Per Pole;
|