Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection, RCCB;
Operation Current: 30mA-100mA-300mA;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: AC/DC Series Moulded Case Circuit Breaker MCCB;
Rated Current: 63A 80A 100A 125A 250A 160A,200A,225A,250A,400A,;
Ue Rated Operating Voltage(DC): 3p 750V/4p 1000V;
Rated Insulation Voltage Ui(VDC): DC1000V;
Rated Impact Voltage Uimp(Kv): 8kv;
Ultimate Breaking Capacity ICU(Kv): 25kv;
Trip Type: Therminal-Magnetic;
Ambient Temperature: -20~70;
Altitude: 2000m;
Instalation: Fixed,Plug in;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Product Name: Jn15-12 Earthing Switch;
Orign of Place: Zhejiang, China;
Related Voltage: up to 12kv;
Rated Frequency: 50/60Hz;
Rated Short Time Withstand Current: 31.5ka;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 2000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Outdoor Vacuum Circuit Breaker;
Related Voltage: up to 40.5kv;
Rated Frequency: 50/60Hz;
Rated Current: up to 2000A;
Phase: Three;
Certificate: ISO CCC IEC;
OEM: Offered;
MOQ: 1PCS;
Weight: 800kg;
Mechanical Life: 10000 Times;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: AC/DC Series Moulded Case Circuit Breaker MCCB;
Rated Current: 63A 80A 100A 125A 250A 160A,200A,225A,250A,400A,;
Ue Rated Operating Voltage(DC): 3p 750V/4p 1000V;
Rated Insulation Voltage Ui(VDC): DC1000V;
Rated Impact Voltage Uimp(Kv): 8kv;
Ultimate Breaking Capacity ICU(Kv): 25kv;
Trip Type: Therminal-Magnetic;
Ambient Temperature: -20~70;
Altitude: 2000m;
Instalation: Fixed,Plug in;
|