Specification |
Application: Power, Electronic, Instrument, Lighting;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Brand: Hero;
Rated Capacity: 2500kVA;
Rated Voltage Ratio: 10kv/0.4kv;
Impedance Voltage: 6.0;
No Load Loss: 2290W;
on Load Loss: 21200W;
Weight: 4850kg;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hfy;
High Voltage: 11kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou Electric;
High Voltage: 6kv/10kv/35kv;
Low Voltagewinding: 0.4kv 0.415kv;
Frequency: 50Hz/60Hz;
Rated Capacity: 50-31500 kVA;
Connection Group: Dyn11;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
Ambient Temperature: -40ºC -+ 40ºC;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Coil Material: Copper;
Iron Core: Silicon Iron Core;
Tap Range: +-2*2.5,+-5;
Rated Capacity: 5-160kVA;
No-Load Loss: 36-232W;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Coil Material: Copper;
Iron Core: Silicon Iron Core;
Tap Range: +-2*2.5,+-5;
Rated Capacity: 5-160kVA;
No-Load Loss: 36-232W;
|