Specification |
After-sales Service: 1.5 Years;
Warranty: 1.5 Years;
Application: Industry, School, Hospital, Lab;
Customized: Customized;
Structure: Desktop;
Material: Alloy;
Type: Hot Plate;
Name: 2L Scientific Equipment Electromagnetic Hot Plate;
Heating Plate Material: Ceramic Coated Aluminum (White or Black);
Volume: 15L;
Heating Power(W): 600;
Temperature Range: Rt ~ 320 Degrees;
Mixing Speed: 100 ~ 1800rpm;
Temperature Control: Pid Auto Control;
Temperature Display: Digital LCD Display;
Usage: High Temperature Sintering;
|
After-sales Service: 1 Year Warranty;
Warranty: 1 Year Warranty;
Application: Industry, School, Hospital, Lab;
Customized: Customized;
Structure: Desktop;
Material: Stainless Steel;
Type: Heating Mantle;
Product Name: Semi-Automatic Oxygen Bomb Calorimeter;
Model No: Nby-1A+;
Heat Capacity: 14000 J/K~15000 J/K;
Measuring Range: (10~35)Degree;
Resolution: 0.001 K;
Measurement Accuracy: +-60j/G;
Repeatability Error: 0.2% (Grade C);
Pressure Endurance of Oxygen Bomb: 20 MPa;
Ambient Temperature: 10 ~28 Degree;
Relative Humidity: Within 85%;
Power Supply: 220V 50Hz;
Dimension: 600mm×480mm×460mm;
|
After-sales Service: 1 Year Warranty;
Warranty: 1 Year Warranty;
Application: Industry, School, Hospital, Lab;
Customized: Customized;
Structure: Desktop;
Material: Stainless Steel;
Type: Heating Mantle;
Product Name: Semi-Automatic Oxygen Bomb Calorimeter;
Model No: Nby-1A+;
Heat Capacity: 14000 J/K~15000 J/K;
Measuring Range: (10~35)Degree;
Resolution: 0.001 K;
Measurement Accuracy: +-60j/G;
Repeatability Error: 0.2% (Grade C);
Pressure Endurance of Oxygen Bomb: 20 MPa;
Ambient Temperature: 10 ~28 Degree;
Relative Humidity: Within 85%;
Power Supply: 220V 50Hz;
Dimension: 600mm×480mm×460mm;
|
After-sales Service: 1 Year Warranty;
Warranty: 1 Year Warranty;
Application: Industry, School, Hospital, Lab;
Customized: Customized;
Structure: Desktop;
Material: Stainless Steel;
Type: Heating Mantle;
Product Name: Semi-Automatic Oxygen Bomb Calorimeter;
Model No: Nby-1A+;
Heat Capacity: 14000 J/K~15000 J/K;
Measuring Range: (10~35)Degree;
Resolution: 0.001 K;
Measurement Accuracy: +-60j/G;
Repeatability Error: 0.2% (Grade C);
Pressure Endurance of Oxygen Bomb: 20 MPa;
Ambient Temperature: 10 ~28 Degree;
Relative Humidity: Within 85%;
Power Supply: 220V 50Hz;
Dimension: 600mm×480mm×460mm;
|
After-sales Service: Permanent;
Warranty: 1 Years;
Application: Industry, School, Hospital, Lab;
Customized: Non-Customized;
Structure: Desktop;
Material: PFA;
Type: Hot Plate;
Product Material: PTFE/PFA;
Product Properties: Metal Element Blank Value Is Low;
Product Function: Distillation and Purification;
Product Application Industry: Geology and Mining/Semiconductor;
|